My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
Onsite sewage treatment system
Orono
>
Property Files
>
Street Address
>
W
>
Watertown Road
>
4545 Watertown Road - 31-118-23-24-0004
>
Permits/Inspections
>
Onsite sewage treatment system
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 4:30:24 PM
Creation date
12/16/2019 11:00:05 AM
Metadata
Fields
Template:
x Address Old
House Number
4545
Street Name
Watertown
Street Type
Road
Address
4545 Watertown Road
Document Type
Permits/Inspections
PIN
3111823240004
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
5
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
i: ()40 <br /> , 0,,. CITY of ORONO <br /> \ Ij ,; _. ,I� 4, Municipal Offices <br /> � lil,�-�' �G Street Address: Mailing Address: <br /> g04' <br /> P.O. Box 66 2750 Kelley Parkway <br /> Orono, MN 55356 Crystal Bay, MN 55323-0066 <br /> Owner: D-e-c-s,-- l , `6 \ Address: I-15H 5 vvck+ertow-,. Ki <br /> City Ordinance 199 requires that each existing on-site sewage treatment system in Orono be inspected every two years. <br /> The on-site sewage treatment system at the above address has been inspected and appears to fall into the categories checked below. <br /> SYSTEM CONFORMITY (1-31: I <br /> 10 "CODE SYSTEM" An ISTS which meets all the location,design and construction standards of the current Orono Municipal Code. <br /> 2 "COMPLIANT SYSTEM" An ISTS which does not meet all the location,design and construction standards of the current Orono Municipal <br /> Code but does meet the three foot separation requirement,and which is not failing or an imminent threat to public health or safety. <br /> 3 "NON-COMPLIANT SYSTEM" A prohibited ISTS;an ISTS located within a designated 100-year flood plain,any ISTS which may <br /> or may not meet all the location,design,or construction standards of the current Orono Municipal Code and which is failing for any reason;and <br /> any ISTS with less than three feet of unsaturated soil or sand between the distribution device and the limiting soil characteristics. <br /> TANK CONDITION(5-10): S <br /> T inspection indicates: <br /> 5 Pumpout not needed at this time. <br /> T <br /> 6 Tank must be pumped out this year (city code requires tanks to be pumped out every 3 years. Tank was last pumped C—J r <br /> —6 C) ). <br /> 7 Solids accumulation in tanks is at a critical a critical level Tanks should be pumped out as soon as possible. <br /> 8 System is discharging to the surface. Tanks must be pumped out within 48 hours to eliminate surface discharge. <br /> 9 Inspection risers missing-tanks could not be inspected Inspection risers(4"dia.pipe)must be installed in each tank at next pumpout If tanks <br /> have not been pumped out within the last three years,they should be pumped out now. <br /> 10 Inspection pipe is located directly over tank baffle(does not give accurate measurement of solids accumulation). If tanks have not been pumped <br /> out within the last three years,they should be pumped out now. <br /> II• • I I LD CONDITION(11-141: \\ <br /> • eld is dry,no surfacing evident. <br /> 12 Some evidence of surfacing,not critical yet <br /> 13 Drainfield is saturated and visibly discharging untreated effluent to the surface. Contact the City Inspector immediately.Repairs must be <br /> completed within 90 days. <br /> 14 Drainfield extent and condition unknown. <br /> COMMENTS: S —I S-TP 1 Dd\CS d K <br /> • <br /> Date of Inspection Septic System Inspector <br /> Note: In the event that this inspectionreport is used to <br /> ep satisfy the requirements'for a moitgage or other transfer of property,be advised that this report does not guarantee <br /> or certify that an existing system will continue to function properly,but is merely an opinion of the adequacy of the system under current conditions based on the available <br /> information. <br />
The URL can be used to link to this page
Your browser does not support the video tag.