Laserfiche WebLink
05-27-94 <br /> 60601903 . 15 <br /> SUMMARY REPORT <br /> Prepared For : Prepared By : <br /> HIGHVIEW JIM <br /> 110 Anystreet TOTALAIRE <br /> Anytown , MN 00000 Job Name : BROLL <br /> *************************************************************************** <br /> DESIGN CONDITIONS for Anytown <br /> OUTDOOR INDOOR <br /> SUMMER. WINTER SUMMER WINTER <br /> Dry Bulb 90 -16 72 68 <br /> Wet Bulb 72 50 <br /> Daily Range 22 Daily Swing 3 . 0 <br /> Latitude 44 Elevation 822 <br /> Safety Factor (%) 10 <br /> Latent Factor (%) 27 <br /> *************************************************************************** <br /> Sensible <br /> Room Heating Heating Cooling Cooling <br /> Name BTUH CFM BTUH CFM <br /> Basement 18, 541 259 6 , 302 318 <br /> Living Room 7 , 900 110 7 ,424 375 <br /> Dining Room 4, 058 57 2,450 124 <br /> Family Room 9,622 135 6 ,624 335 <br /> LAUNDRY 4 ,483 63 1, 096 55 <br /> Bedroom 1 3 , 045 43 2, 052 104 <br /> Bathroom 5,761 81 2, 821 142 <br /> Bedroom 2 2, 510 35 1,605 81 <br /> HALL 2, 580 36 1,701 86 <br /> FLAT 1, 866 26 988 50 <br /> 60, 365 844 33 , 064 1,670 <br /> HEATING DELTA T 65 . 0 COOLING DELTA T 18 . 0 <br /> NOTE : *** Calculated Airflow is based upon load requirements . <br /> Verify that airflow calculated is compatible with <br /> selected equipment requirements . *** <br />