My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1996-008511 - new septic
Orono
>
Property Files
>
Street Address
>
W
>
Watertown Road
>
4520 Watertown Road - 31-118-23-21-0002
>
Septic
>
1996-008511 - new septic
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 4:29:34 PM
Creation date
12/16/2019 9:53:40 AM
Metadata
Fields
Template:
x Address Old
House Number
4520
Street Name
Watertown
Street Type
Road
Address
4520 Watertown Road
Document Type
Septic
PIN
3111823210002
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
28
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
RE: Septic system design and <br /> percolations tests for: <br /> 4520 Watertown Rd <br /> Orono MN <br /> 1-lennepin County <br /> We were retained by Mr. Miller to evaluate this site for suitability of an individual sanitary <br /> sewage treatment system to handle the sewage flow generated by water-use appliances within a <br /> single family dwelling. <br /> PROCEDURE <br /> A total of six(6)soil percolation tests were performed on May 16, 1995 in areas to the northeast <br /> of the proposed house. Three additional percolation tests were performed on November 10, <br /> 1995 to the west of the proposed house, <br /> In addition , six(6)soil boring's were drilled with a 2" i.d.x 3 114" o.d. Hand auger to check for <br /> the position of the ground water table and to identify the underlying soil types. Location of tests <br /> and boring's are shown on the site plan. Three additional sil borings were drilled on November <br /> 12, 1995. <br /> The percolation tests were performed in accordance with the provisions of"Minnesota Pollution <br /> Control Agency Rules and Standards Chapter 7080". The percolation test holes were drilled to a <br /> alternate mound depth of 12 inches with a 5" i.d. x 6" ad. auger. Two inches of pea gravel were <br /> placed in the bottom of each hole to prevent scoring, Water was then added to the test holes and <br /> replenished as necessary,maintaining a saturation.,each hole was refilled to a 12-inch head of <br /> water over the bottom,and the percolation tests commenced. <br /> Based on the soils this let will attataia a»,.:t d t-;;p •Ss ptk Intem to handk.nbentes Trastiz.. <br /> water. The site must be protected and roped off by the homeowner or contractor. <br /> All equiptment must be kept off of the septic sites.If the site is distrubed we can and will <br /> not warranty future use. <br />
The URL can be used to link to this page
Your browser does not support the video tag.