Laserfiche WebLink
.-: <br /> CITY OF ORONO O <br /> Municipal Offices O Atop\ <br /> Post Office Box 66 '-- <br /> ,4 V_e. <br /> Crystal Bay, MN 55323-0066r ON—SITE SEWAGE TREATMENT <br /> a <br /> X11�'' ' INSPECTION REPORT <br /> 1 r kP �, <br /> '�ksHa4 <br /> Owner: Jflvaeo O)0/flklS'T) Address: 11300ik)et 7z iota,.') /a �:,7:Jjq <br /> Permit ;II's: tJ `0 [ Dates: h --P1-4 . <br /> Contractors: 1( -1 BM/r z. E/C r <br /> City ordinance number 100 requires that each on-site sewage treatment system in Orono be inspected on a regular basis. <br /> The on-site sewage treatment system at the above address has been inspected and appears to fall into the category <br /> checked below. <br /> (This is Al an existing system I ) new construction) <br /> SYSTEM CONFORMITY (1-3): . <br /> 1 "CODE SYSTEM"-A system which meets all the location, design, and construction standards of the current City <br /> Codes, and which is operating satisfactorily by treating and disposing of the entire current sewage input <br /> without discharging any pollutants into ground or surface waters. <br /> 2 "CONFORMING SYSTEM"-A system which does not meet all the location, design, and construction standards of the <br /> current City Codes, but was installed according to the code in effect at the time of installation, and which <br /> is operating satisfactorily by treating and disposing of the entire current sewage input without discharging <br /> any pollutants into ground or surface waters. <br /> 3 "NON-CONFORMING SYSTEM"-A prohibited system; a system located within a designated 100-year floodplain; any <br /> system which may or may not meet all the location, design, and construction standards of the current City <br /> Codes and which is failing for any reason; and any system with less than 3 feet of unsaturated soil or sand <br /> between the distribution device and the limiting soil characteristics. <br /> (The limiting soil characteristichas or I ] has not been identified at this time. If the limiting soil <br /> characteristic has not been ident fied, this classification may be subject to revision.) <br /> TANK CONDITION (5-10): 5 <br /> inspection indicates: <br /> 5 Pumpout not needed at this time. <br /> Solids accumulation in tanks indicates they should be pumped out this year to help prevent future problems. <br /> 7 Solids accumulation in tanks is at a critical level. Tanks should be pumped out as soon as possible. <br /> 8 System is discharging to the surface. Tanks must be pumped out within 48 hours to eliminate surface discharge. <br /> 9 Inspection risers missing-tanks could not be inspected. Inspection risers (4" dia. pipe) must be installed in each <br /> tank at next pumpout. If tanks have not been pumped out within the last three years, they should be pumped <br /> out now. <br /> 10 Inspection pipe is located directly over tank baffle (does not give accurate measurement of solids accumulation). <br /> If tanks have not been pumped out within the last three years, they should be pumped out now. <br /> DRAINFIELD CONDITION (11-14): I,' <br /> D field inspection indicates: <br /> 11 Drainfield is dry, no surfacing evident. <br /> Some evidence of surfacing, not critical yet. <br /> 13 Drainfield is saturated and visibly discharging untreated effluent to the surface. Contact the City Inspector <br /> immediately. Repairs must be completed within 90 days. <br /> 14 Drainfield extent and condition unknown. <br /> LIMITING SITE FACTORS (slope,setbacks.etc.):---r----, <br /> POTENTIAL FOR SYSTEM FAILURE (depends on soits,water table,etc.): r fr �J <br /> COMMENTS: 57`�'� 11 <br /> 6✓1 1S M-(ri,?TC,2{,ctIart dcu) 7t,` a) lGCGS or a> - v..4,4_,v..4v..4,4_, Iz <br /> , 'cf S-clnara-liorii <br /> he-II-002A% prf(i£41'r �F l di Ln TtL'Y✓1 aad se,l,c# a!O/e P.)6rft=-`7L Le('e r 5><e, /LW 743 ad v <br /> V`P�61 k.k,0to( 11y l7 ?I-- zc,r�7, j <br /> r /(-6 -- `l (OlP r <br /> Date of Inspection Septic System for <br /> Note: In the event that this inspection report is used to satisfy the requirements for a mortgage or other transfer of <br /> property, be advised that this report does not guarantee or certify that an existing system will continue to function <br /> properly, but is merely an opinion of the adequacy of the system under current conditions based on the available <br /> information. <br /> This report must be kept on the premises with the system location and pumping records. <br /> WHITE COPY/Inspectors File YELLOW COPY/Homeowner <br />