Laserfiche WebLink
At <br /> CITY OF ORONO 0 <br /> Municipal Offices 14; <br /> O <br /> Post Office Box 66 '-=- <br /> Crystal Bay, MN 55323-0066 \ l ON—SITE SEWAGE TREATMENT <br /> IA ' ^Ir1 INSPECTION REPORT <br /> '4 104)4(i,'a,HM;�1�40 <br /> 4;4 <br /> kESo <br /> Owner: ' G G f Address: '(z70 Ella f ,& (&12-itiOel <br /> !f o&-4 (57,,q50 <br /> Permit #'s: 76 q Dates: /0 (2- 76 //'. <br /> 7 — ( 6Contractors: St( (ft V '� <br /> City ordinance number 100 requires that each on-site sewage treatment system in Orono be inspected on a regular basis. <br /> The on-site sewage treatment system at the above address has been inspected and appears to fall into the category <br /> checked below. <br /> (This is X an existing system [ ] new construction) <br /> SYSTEM CONFORMITY (1-3): ,. <br /> 1 "CODE SYSTEM"-A system which meets all the location, design, and construction standards of the current City <br /> Codes, and which is operating satisfactorily by treating and disposing of the entire current sewage input <br /> without discharging any pollutants into ground or surface waters. <br /> 2 "CONFORMING SYSTEM"-A system which does not meet all the location, design, and construction standards of the <br /> current City Codes, but was installed according to the code in effect at the time of installation, and which <br /> is operating satisfactorily by treating and disposing of the entire current sewage input without discharging <br /> any pollutants into ground or surface waters. <br /> 3 "NON-CONFORMING SYSTEM"-A prohibited system; a system located within a designated 100-year floodplain; any <br /> system which may or may not meet all the location, design, and construction standards of the current City <br /> Codes and which is failing for any reason; and any system with less than 3 feet of unsaturated soil or sand <br /> between the distribution device and the limiting soil characteristics. <br /> (The limiting soil characteristic has or has not been identified at this time. If the limiting soil <br /> characteristic has not been identiie , this ssification may be subject to revision.) <br /> TANK CONDITION (5-10): 9 <br /> Tank inspection indicates: <br /> 5 Pumpout not needed at this time. <br /> 6 Solids accumulation in tanks indicates they should be pumped out this year to help prevent future problems. <br /> 7 Solids accumulation in tanks is at a critical level. Tanks should be pumped out as soon as possible. <br /> System is discharging to the surface. Tanks must be pumped out within 48 hours to eliminate surface discharge. <br /> (OP)(:4:, <br /> Inspection risers missing-tanks could not be inspected. Inspection risers (4" dia. pipe) must be installed in each <br /> tank at next pumpout. If tanks have not been pumped out within the last three years, they should be pooped <br /> out now. <br /> 10 Inspection pipe is located directly over tank baffle (does not give accurate measurement of solids accumulation). <br /> If tanks have not been pumped out within the last three years, they should be pumped out now. <br /> DRAINFIELD CONDITION (11-14): /l <br /> 10 <br /> r field inspection indicates: <br /> � Drainfield is dry, no surfacing evident. <br /> Some evidence of surfacing, not critical yet. <br /> 13 Drainfield is saturated and visibly discharging untreated effluent to the surface. Contact the City Inspector <br /> immediately. Repairs must be completed within 90 days. <br /> 14 Drainfield extent and condition unknown. <br /> LIMITING SITE FACTORS (slope,setbacks,etc.): .._.-- <br /> POTENTIAL FOR SYSTEM FAILURE (depends on soils,water table,etc.): /0 <br /> COMMENTS: 5 /S -Cdl'17C�RGh/�tr / ` <br /> dy, • G.J (4 C`c d tiY %I s >! 11�2 Q�tJ <br /> )ra'l vl,("i ) 6.= 0. rJ✓� - 50ast1.tell n &lP. _4y6i44 4 ,; � Vu247ace/ &.y, /2-�I-XV7. <br /> /1 ~ v r- ?? -.s-' <br /> Date of Inspe6tion Sep is Sy'§tem Inspector <br /> Note: in the event that this inspection report is used to satisfy the requirements for a mortgage or other transfer of <br /> property, be advised that this report does not guarantee or certify that an existing system will continue to function <br /> properly, but is merely an opinion of the adequacy of the system under current conditions based on the available <br /> information. <br /> This report must be kept on the premises with the system location and pumping records. <br /> WHITE COPY/Inspectors File YELLOW COPY/Homeowner <br />