Laserfiche WebLink
( THE CONSTRUCTION METHODS ILLUSTRATED APPLY <br /> 0°' CORNER BRACKET ONLY TO NORMAL GROUND CONDITIONS. IF UNUSUAL <br /> SOIL CONDITIONS ARE ENCOUNTERED (I.E. HIGH <br /> �p N/T" x 1" ASLT WITH ORGANIC MATERIAL, HIGH WATER LEVEL) ADDITIONAL <br /> NUT & 2 WASHERS MEASURES MUST BE TAKEN TO PROVIDE SUBSURFACE <br /> (TYP. 14 EA CORNER) CONDITIONS WITHIN THE STRUCTURAL CAPABILIES <br /> �\„><1,P-440.0, <br /> °: OF THE PANEL. ANY ADDITIONAL PRECAUTIONS OR <br /> QpX> _ M, <br /> J) , METHODS OF CONSTRUCTION ARE THE RESPONSIBIUTY <br /> stkO �; ' OF THE CONTRACTOR. (NOTE: DECK SUPPORTS ARE <br /> OPTIONAL) <br /> / 3/8” x 1" BOLT WITH BIG VEE POOL DECK <br /> NUT & 2 WASHERS 6" RAD. INSERT <br /> \ (7 PERREO'D.)111 RADIUS CORNER <br /> COPING �71614911111111,1,1111,111111H----. �...„ i <br /> ;11/20; sTEEL 14 cA ,,,,,, <br /> TYPICAL CORNER DETAIL .:.: ,, `' <br /> S(' <br /> ,, illy <br /> (G235)GALVANIZING (RECTANGULAR POOLS) .` ;�� °", <br /> `�JiiiA I U .e V''':•,'"''''41(,, <br /> 4 MIN. B" THICK CONCRETE COLLAR I'- <br /> REQ'D. AT BASE OF WALL PANELS <br /> 11. <br /> :7 `' a ;. <br /> y� DRNE RODS THROUGH ;�►� �� <br /> HOLES IN PANELS .�. <br /> �r� INTO UNDISTURBED EARTH. ,1 " <br /> 3/8" x 2 1/2" BOLT W/NUT <br /> 2" SAND OR VER/A. • . , <br /> REINF. ROD ,� <br /> SUPPORT CURVED CORNER <br /> BRACE TIE COPING <br /> � SBOLTED TO THf.ANGLE. / <br /> POST IN ANY OF NE PRE- <br /> UNDISTRUBED <br /> PUNCHED HOLES. EARTH <br /> TYPICAL WALL BRACE ASSEMBLY BACKFILL SHALL FREE-DRAINING <br /> CLEAR GRALAB MATERIAL SUCH <br /> AS SAND, TRACE CLAY OR TRACE SILT. <br /> CORNER BRACKETTYP. LINER 'INSTALLATION DET. <br /> 3/8" x 2" BENT BOLT <br /> CONCRETE DECK REVD. W/PEER&02WASHERS <br /> "'-' \ TYPICAL CORNER DETAIL <br /> 1 RIM-LOK COPING (GRECIAN POOLS) <br /> EXTRUDED ALUMINUM PLANNING NOTES: <br /> 12-14 x 1" SELF DRILLING t <br /> FASTENER (18` O.C.) SET WIDTH OF POOL AT RIGHT ANGLES TO SLOPE <br /> ii.: . FINISHED ELEVATION OF DECK TO BE 1'00" ABOVE <br /> SURROUNDING GRADE <br /> I - ��I VYNYL UNER . PROVIDE SWALE AROUND UP-HILL SIDE OF DRAIN. <br /> I (HUNG) SURFACE WATER AWAY FROM POOL <br /> 1 . CONCRETE DECK SHOULD SLOPE MIN. 1/4" PER FOOT <br /> f AWAY FROM POOL <br /> . PLOT PLAN FURNISHED BY OWNER TO SHOW POOL <br /> POOL WALL PANEL LOCATION AND ENCLOSURE. <br /> RIM—LOK COPING DETAIL . ELECTRICAL, PLUMBING AND FENCING TO CONFORM TO CARDINAL SYSTEMS <br /> ALL CODES. w + (570)366-4133 386-1118 <br /> NOTES: . OPTIONS EXTRA IF REQ'D. BY SITE coNDmoNs OR <br /> SCIRMALLWHEN SPECIFIED BY OWNER. Mt <br /> 11'4E' 't <br /> : 3/16/02 "tONSTR. DET. SHT. <br /> MEETS MINIMUM STANDARDS OF THE INTERNATIONAL RESIDENTIAL . AT LEAST ONE MEANS OF EGRESS SHALL BE PROVIDED. 'sc.. NONE HUNG LINER STL. POOL <br /> CODE 2006 AG103.1(ANSI/NSPI-5 2003) AND BOCA1996. OPTIONAL STAIRS OR LADDER tswiat PEB " 14" CONSTDET <br />