Joseph Olson D.B.A. <br /> Rusty Olson's--Soil and Percolation Testing <br /> Joseph J. Olson—MPGA License#810 <br /> 11481 Riverview Rd.NE,Hanover,MN 55341 <br /> (763)498-8779 Fax(763)498-8290 <br /> Revised October 13, <br /> Pillar Homes <br /> 3955 Watertown Road <br /> Orono,Hennepin County <br /> This on-site Sewage Treatment System is designed for a Type 1,Five-bedroom home in accordance with <br /> the Minnesota Pollution Control Agency Chapter 7080 and local ordinances. <br /> The periodically saturated soils were located at 12"-16"(mottled soil).Due to the periodically saturated <br /> soils,a pressurized mound system will need to be installed to treat the septic effluent.The bottom of the <br /> treatment area must be located at least 3'above the saturated soils. <br /> The soils at a depth of 12"have a percolation rate averaging 12AMPI. <br /> The absorption areas due not overlap. <br /> All tanks need to be insulated if there is less than two feet of cover over the top of the tanks.Clean outs <br /> must be installed on the end of the laterals for maintenance. <br /> Use 7/32 inch perforations on the laterals. <br /> All neighboring wells are greater than 100'from proposed treatment areas. <br /> A 1300 gallon pumping chamber will need to be installed to lift the effluent to the treatment area.The <br /> power supply and Switches must be located outside the manhole and pumping chamber in a weatherproof <br /> enclosure.A warning device must be installed with light and sound devices;this is in case of a pump <br /> failure.The manifold and supply line must have back drainage to the pumping chamber. <br /> Keen all heavy eauioment off of the or000sed treatment areas before,during and after construction. <br /> The area around both sites must be fenced off by the contractor before any construction begins. <br /> With proper installation and maintenance,this system should have no problem in treating septic effluent <br /> effectively.Nothing other than gray water,(laundry,showers,etc.)Human water and toilet tissue should be <br /> disposed of into the septic tanks.Garbage disposals are not recommended.Additives must not be used they <br /> may cause harmful damage to your septic system.It is recommended that you pump the septic tanks every <br /> two years. <br /> Sincerely, CITY OF ORONO <br /> SEPTIC P8 TPJAhl k&VtB'#1 <br /> tNBPfC�1p <br /> Joseph J.Olson <br /> M <br /> �ItO M!'1'It� �IMNM <br /> Mdf A1rMtOYBD•COAR6CTi Rpl1R)tA1' <br /> in fucompce with>K ate MM NO Tor�il your nformeticm t' ic Aan�c ns ` <br /> shall be Qtr <br /> (acquirements including items not specifically noted in thiti rcrirw. <br /> �Iowat. <br />