Laserfiche WebLink
M ; N a /'t <br /> Joseph Olson D.B.A. <br /> Rusty Olson's--Soil and Percolation Testing <br /> Joseph J. Olson--MPCA License #810 <br /> 11481 Riverview Rd. NE, Hanover, MN 55341 <br /> (763) 498-8779 fax(763) 498-8290 <br /> January 17,2013 Q'RONQ <br /> Pillar Homes CO <br /> 3955 Watertown Road <br /> Orono,Hennepin County <br /> This on-site Sewage Treatment System is partially designed for a Type 1,five-bedroom home in <br /> accordance with the Minnesota Pollution Control Agency Chapter 7080 and local ordinances. <br /> Once the house size,location and septic primary and future sites are chosen this design can be completed. <br /> The seasonally saturated soils were located at 12"-16"(mottled soil).Due to seasonally saturated soils,a <br /> pressurized Mound System will need to be installed to treat septic effluent.The bottom of the treatment <br /> area must be located at least 3'above the saturated soils. <br /> The soils at a depth of 12"have a percolation rate averaging 12.6MP1. <br /> Due to limited,space on the lot.Site A and Site B are combined.The absorption areas do not overlap. <br /> All tanks need to be insulated if there is less than two feet of cover over the top of the tanks.A filter needs <br /> to be installed on the second tank.Clean outs must be installed on the end of the laterals for maintenance. <br /> A pumping chamber will need to be installed to lift the effluent to the treatment area.The power supply and <br /> switches must be located outside the manhole and pumping chamber in a weatherproof enclosure.A <br /> warning device must be installed with a light and sound device;this is in case of a pump failure. <br /> Use 7/32 inch perforations on the laterals <br /> Keep all heavy equipment off of the proposed treatment areas before and after construction.The C <br /> treatment area must be fenced off before construction begins.This Design is not valid&the System � <br /> will need to be relocated if failure to protect the areas proposed for the On-Site Sewage Treatment .�, <br /> systems occurs. O <br /> n <br /> Nothing other than gray water,(laundry,showers etc.)Human water and toilet tissue should be �rd� <br /> disposed of into the seotic tanks.Garbage disposals are not recommended Additives must not be <br /> used:they may cause harmful damage to your septic system It is recommended that you pump the <br /> tanks every two years. <br /> S., cerely, <br /> �JOlson <br /> C"OF ORONO <br /> SEPTIC PE T Irl REV>JkEW <br /> INSPECTO <br /> DATE — ERMIT NO.,,,,,_,,�,,, <br /> El APPROVED AS SUBMITTED <br /> APPROVED WITH CORRECTIONS AS NOTED <br /> ORONO CO NOT APPROVED-CORRECT& RESUItV11T <br /> PY These comments are Im your information. All work shall he clone <br /> I. full compliance with all applicable septic and coning code. <br /> Requirements including items not specilically noted in this rc\iew. <br /> KEEP THIS PLAN SET ON SH E AT AL L.l 0,11..5 <br />