Laserfiche WebLink
OSTP Pressure Distribution Aa <br /> UNIVERMinnesota Pollution SITY <br /> Control Agency esn Worksheet OF MINNESOT <br /> x <br /> "'- <br /> 12. Select Type of Manifold Connection (End or Center): End center <br /> 13. Select Lateral Diameter: 2.00 in Table II <br /> Volume of Liquid in <br /> 14. Volume of Liquid Per Foot of Distribution Piping: 0.170 Gallons/ft pipe <br /> 15. Volume of Distribution Piping = Pipe Liquid <br /> Diameter Per Foot <br /> _[Number of Perforated Laterals (Line 1)X Length of Laterals (Line 4)X (inches) (Gallons) <br /> (Volume of Liquid Per Foot of Distribution Piping(Line 14)] 1 0.045 <br /> X 61 ft X 0.170 gal/ft = 31.1 Gallons 1.25 0.078 <br /> 1.5 0.110 <br /> 16. Minimum Dose=Volume of Distribution Piping(Line 15)X 4 2 0.170 <br /> EJ 0 <br /> 31.1 gals X 4 = 1 24.4 Gallons 4 0.3 0.3838 <br /> 661 <br /> marno pipe, <br /> _-Cleanouts -------- - <br /> I <br /> pipe from pump Manifold pipe, <br /> lean outs ---- <br /> Alternate location <br /> of pipe from pump <br /> alternate location <br /> of ae from purrij Pipe from pump <br /> Comments/Special Design Considerations: <br />