I F 0 R T E d Main Level,Mudroom Entry Door PASSED <br /> 2 piece(s) 2 x 10 Spruce-Pine-Fir No. 1 / No. 2 <br /> Overall Length:3'1" <br /> + + <br /> o a <br /> 2'10" <br /> 111 CI <br /> All locations are measured from the outside face of left support(or left cantilever end).All dimensions are horizontal.;Drawing is Conceptual <br /> Design Results Actual 0 Location Allowed Result LDF Load:Combination(Pattern) System:Wall <br /> Member Reaction(Ibs) 1760 @ 0 1913(1.50") Passed(92%) -- 1.0 D+1.0 L(All Spans) Member Type:Header <br /> Shear(lbs) 737 @ 10 3/4" 2498 Passed(30%) 1.00 1.0 D+1.0 L(All Spans) Building Use:Residential <br /> Moment(Ft-lbs) 1356 @ 1'6 1/2" 3431 Passed(40%) 1.00 1.0 D+1.0 L(All Spans) Building Code:IBC 2012 <br /> Live Load Defl.(in) 0.006 @ 1'6 1/2" 0.103 Passed(1/999+) -- 1.0 D+1.0 L(All Spans) Design Methodology:ASD <br /> Total Load Dell.(In) 0.008©1'6 1/2" 0.154 Passed(1/999+) -- 1.0 D+1.0 L(All Spans) <br /> •Deflection criteria:LL(1/360)and TL(L/240). <br /> •Bracing(Lu):All compression edges(top and bottom)must be braced at 3'1"o/c unless detailed otherwise.Proper attachment and positioning of lateral <br /> bracing Is required to achieve member stability. <br /> •Applicable caladatlons are based on NDS. <br /> Bearing loads to Supports(lbs) <br /> Supports Total Available Required Dead L�ivoar Total Accessories <br /> 1-Trimmer-SPF 1.50" 1.50" 1.50" 488 1272 1760 None <br /> 2-Trimmer-SPF 1.50" 1.50" 1.50" 488 1272 1760 None <br /> Tributary Dead Floor Live <br /> Loads Location(Side) Width (0.90) (1.00) Comments <br /> 0-Self Weight(PLF) 0 to 3'1" N/A 7.0 <br /> 1-Uniform(PSF) 0 to 3'1' 20'7 1/2" 15.0 40.0 Floor-Upper Level //�� <br /> Weyerhaeuser Notes (lam SUSTAINABLE FORESTRY INITIATIVE <br /> Weyerhaeuser warrants that the sizing of Its products will be in accordance with Weyerhaeuser product design criteria and published design values. err <br /> Weyerhaeuser expressly disclaims any other warrenWs related to the software.Refer to arrant Weyerhaeuser literature for installation details. <br /> (www.woodbywy.com)Accessories(Rim Board,Bloddng Panels and Squash Blocks)are not designed by this software.Use of this software Is not Intended to <br /> circumvent the need for a design professional as determined by the authority having jurisdiction.The designer of record,builder or framer is responsible to <br /> assure that this calculation Is compatible with the overall project Products manufactured at Weyerhaeuser faditties are third-party certified to sustainable <br /> forestry standards.Weyerhaeuser Engineered Lumber Products have been evaluated by ICC ES under technical reports ESR-1153 and ESR-1387 and/or tested in <br /> accordance with applicable ASTM standards. For current code evaluation reports refer to http://www.woodbywy.com/services/s_CodeReports.aspx. <br /> The product appicatlon,input design loads,dknenslons and support Information have been provided by Gonyea;plan dated 9/29/2016. <br /> Forte Software Operator Job Notes 10/20/2016 3:23:05 PM <br /> Jeffrey Doty,Design Supervisor Gonyea Homes-GHC660 Forte v5.1.Design Engine:V6.5.1.1 <br /> Lyman Lumber Company 780 Lakeview Parkway:Orono.MN 780 Lakeview Parkway;Orono, MN.4te <br /> ;952)470-4866 Evenson Residence <br /> Jeff dotyalymunlumber.corn 1020/2016,'121554 Page 24 of 32 <br />
The URL can be used to link to this page
Your browser does not support the video tag.