Laserfiche WebLink
F 0 R T E " • Upper Level,Master Bedroom Window PASSED <br /> 3 piece(s) 2 x 10 Spruce-Pine-Fir No. 1 / No. 2 <br /> Overall Length:11'9" <br /> 0 0 <br /> 'r 3' '11'S ' ,r• <br /> 3' <br /> • 'r <br /> CI II LI <br /> All locations are measured from the outside face of left support(or left cantilever end).All dimensions are horizontal.;Drawing is Conceptual <br /> Design Results Actual 0 Location Avowed Result LDF Load:Combination(Pattern) System:Wan <br /> Member Reaction(lbs) 5349 @ 3'3" 5738(3.00") Passed(93%) -- 1.0 D+1.0 S(Adj Spans) Member Type:Header <br /> Shear(lbs) 1927 @ 4'1 3/4" 4308 Passed(45%) 1.15 1.0 D+1.0 S(Adj Spans) Building Use:Residential <br /> Moment(Ft-lbs) -2246 @ 3'3" 5919 Passed(38%) 1.15_1.0 D+1.0 S(Adj Spans) Building Code:IBC 2012 <br /> Live Load Defl.(in) 0.010©5'10 9/16" 0.175 Passed(1/999+) -- 1.0 D+1.0 S(Alt Spans) Design Methodology:ASD <br /> Total Load Def.(in) 0.015 @ 5'10 9/16" 0.262 Passed(L/999+) — 1.0 D+1.0 S(Alt Spans) <br /> • Deflection criteria:LL(L/360)and TL(1/240). <br /> • Bracing(Lu):All compression edges(top and bottom)must be braced at 11'9"o/c unless detailed otherwise.Proper attachment and positioning of lateral <br /> bracing is required to achieve member stability. <br /> •Applicable calculations are based on NDS. <br /> Bearing Loads to Supports(ibs) <br /> Supports Total Available Required Dead Snow Total Accessories <br /> 1-Trimmer-SPF 1.50° 1.50" 1.50" 402 855 1257 None <br /> 2-Trimmer--SPF 3.00" 3.00" - •2.80" 1955- 3393 5348 None <br /> 3-Trimmer-SPF 3.00" 3.00" 2.75" 1919 3334 5253 None• <br /> 4-Trimmer-SPF 1.50" 1.50" 1.50" 281 643 924 None <br /> Tributary Dead Snow <br /> Loads Location(Side) Width (0.90) (1.15) Comments <br /> 0-Sail Weight(PLF) 0 to 11'9" N/A 10.6 <br /> 1-Uniform(PSF) 0 to 10'9" 19'6" 20.0 35.0 Snow-Main <br /> 2-Uniform(PSF) 10'9"to 11'9" 12' 20.0 35.0 Snow-Main <br /> Weyerhaeuser Notes <br /> Weyerhaeuser warrants that the sizing of its products will be In accordance with Weyerhaeuser product design criteria and published SUSTAINABLE FORESTRY INITIATIVE <br /> Weyerhaeuser expressly disclaims any other warranties related to the software.Refer to current Weyerhaeuserru design values. <br /> (www.woodbywy.com)Accessories(Rim Board,BlockingPanels andsoftware. <br /> Use for installation re Is n <br /> circumvent the need for a designSquash Blocks)are not tion.designed by this software. builderof software Is not Intended to <br /> g professional as determined by the authority having jurisdiction.The designer of record, or framer Is responsible to <br /> assure that this calculation is compatible with the overall project.Products manufactured at Weyerhaeuser Willies are third-party certified to sustainable <br /> forestry standards.Weyerhaeuser Engineered Lumber Products have been evaluated by ICC ES under technical reports ESR-1153 and ESR-1387 and/or tested in <br /> accordance with applicable ASTM standards. For current code evaluation reports refer to http://www•woodbywy.com/servkws/s_CodeReports.aspc. <br /> The product application,Input design loads,dimensions and support Information have been provided by Gonyea;plan dated 9/29/2016. <br /> Forte Software Operator Job Notes 10/20/2016 3:23:05 PM <br /> Jeffrey Doty.Design Supervisor Gonyea Homes-GH0660 Forte v5.1, Design Engine.V6.5.1.1 <br /> Lyman Lumber Company 780 Lakeview Parkway;Orono,MN 780 Lakeview Parkway; Orono,MN.4te <br /> (952)470-4866 Evenson Residence <br /> jeff_doty@lymanIumber.com 10/20/2076,#21554 <br /> Page 5 of 32 <br />