Laserfiche WebLink
a F 0 R T E ; Upper Level,Bedroom#2 Window PASSED <br /> 3 piece(s) 2 x 10 Spruce-Pine-Fir No. 1 / No. 2 <br /> Overall Length:6'6" <br /> dimiimmint <br /> o 0 <br /> o a <br /> All locations are measured from the outside face of left support(or left cantilever end).All dimensions are horizontal.;Drawing is Conceptual <br /> Design Results Actual 0 Location Allowed Result LDF Load:Combination(Pattern) System:Wall <br /> Member Reaction(lbs) 3510 @ 6'4 1/2" 5738(3.00") Passed(61%) — 1.0 D+1.0 S(All Spans) Member Type:Header <br /> Shear(lbs) 2404 @ 5'5 3/4" 4308 Passed(56%) 1.15 1.0 D+1.0 S(All Spans) Building Use:Residential <br /> Moment(Ft-lbs) 5257 @ 3'3 1/8" 5919 Passed(89%) 1.15 1.0 D+1.0 S(All Spans) Building Code:IBC 2012 <br /> Uve Load Den.(in) 0.056 @ 3'2 15/16" 0.208 Passed(L/999+) -- 1.0 D+1.0 S(All Spans) Design Methodology:ASD <br /> Total Load Defl.(in) 0.089©3'2 15/16" 0.313 Passed(1/844) -- 1.0 D+1.0 S(All Spans) <br /> • Deflection criteria:LL(L/360)and TL(1/240). <br /> •Brad®(Lu):AII compression edges(top and bottom)must be braced at 6'6"o/c unless detailed otherwise.Proper attachment and positioning of lateral <br /> bracing Is required to achieve member stability. <br /> •Applicable calculations are based on NDS. <br /> Bearing Loads to Supports(lbs) <br /> Supports Total Available Required Dead Snow Total Accessories <br /> 1-Trimmer-SPF 3.00" 3.00" 1.81" 1283 2185 3468 None <br /> 2-Trimmer-SPF 3.00" 3.00" 1.84" 1298 2212 3510 None <br /> Tributary Dead Snow <br /> Loads Location(Side) Width (0.90) (1.15) conarrents <br /> 0-Self Weight(PLF) 0 to 6'6" N/A 10.6 <br /> 1-Uniform(PSF) 0 to 2'3" 19' 20.0 35.0 Snow-Main <br /> 2-Uniform(PSF) 2'3"to 6'6" 19 6" 20.0 35.0 Snow-Main <br /> Weyerhaeuser Notes SUSTAINABLE FORESTRY INITIATIVE <br /> Weyerhaeuser warrants that the sizing of Its products will be In accordance with Weyerhaeuser product design criteria and published design values. <br /> Weyerhaeuser expressly disclaims any other warranties related to the software.Refer to current Weyerhaeuser literature for Installation details. <br /> (www.woodbjwy.00m)Accessories(Rim Board,Bioddng Panels and Squash Blocks)are not designed by this software.Use of this software Is not intended to <br /> dreumvent the need for a design professional as determined by the authority having jun on.The designer of record,builder or framer Is responsible to <br /> assure that this calculation Is compatible with the overall project.Products manufactured at Weyerhaeuser facilities are third-party certified to sustainable <br /> forestry standards.Weyerhaeuser Engineered Lumber Products have been evaluated by ICC ES under tedmical reports ESR-1153 and ESR-1387 and/or tested in <br /> accordance with applicable ASTM standards. For current code evaluation reports refer to http://www.woodbywy.cram/services/s_CodeRepats.aspa. <br /> The product application,input design loads,dimensions and support Information have been provided by Gonyea;plan dated 9/29/2016. <br /> Forte Software Operator Job Notes 10/20/2016 3:23:05 PM <br /> Forte v5.1.Design Engine:V6.5.1.1 <br /> Jeffrey Doty,Design Supervisor Gonyea Homes-GH0660 <br /> Lyman Lumber Company 780 Lakeview Parkway:Orono.MN 780 Lakeview Parkway;Orono, MN.4te <br /> j952)470-4866 Evenson Residence <br /> teffdoty@lymanIumber.com 10/2012016;#21554 Page 2 of 32 <br />