My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1999-011851 - new septic system
Orono
>
Property Files
>
Street Address
>
W
>
Watertown Road
>
3745 Watertown Road - 32-118-23-34-0012
>
Septic
>
1999-011851 - new septic system
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 4:40:58 PM
Creation date
10/21/2019 2:14:52 PM
Metadata
Fields
Template:
x Address Old
House Number
3745
Street Name
Watertown
Street Type
Road
Address
3745 Watertown Road
Document Type
Septic
PIN
3211823340012
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
25
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Koch Soil Testing <br /> Box 81 <br /> Loretto, MN 55357 <br /> (612) 479-2637 <br /> Date 8/28/99 <br /> Name <br /> Ned Butterfield <br /> 3745 Watertown Rd. <br /> Orono,Minn.. <br /> Job Site;Above Address <br /> The present drainfield is bleeding out onto the surface therefore another site was tested to <br /> determine what type of system could be install and still comply with the local codes and <br /> with the Minn. Rules 7080. <br /> The area that was tested is located South of the present house. <br /> The average percolation rate in this area was 38.4 min/in. the depth to mottled soil was at <br /> 18 inches.. <br /> * See the enclosed percolation tests and soil borings for the details. <br /> *Mottled soil is consider the highsS� yrls that exist methe le <br /> t seasons <br /> (Fall and Spring).The Minn. RuleO80 state thatthe minimum depth to d soil must beat <br /> 48 inches or deeper before a trench drainfield can be installed. <br /> 'Therefore with the above information the only type of drainfield that can be installed in this area is <br /> a pressurized mound system and still comply with the current codes. <br /> The size of mound system needed for a 3 bedroom home would be the following size <br /> Sizing Factors : 1)Daily Water Usage --450 gal/day <br /> 2) Perc. Rate Range --46-60 min/in. ( CLay Loam Soil Factor) <br /> 3)Land Slope--4% <br /> Overall Size--2870 sq.$.. <br /> Upslope Length--65 ft. <br /> Downslope Length---75 ft <br /> Width---41 $ .(Upslope-12$Rock-10 ft Downslope--19 ft). <br /> * Absorption Width-- 271 <br /> Rock Bed Size--410 sq. ft Length--41 $ Width--10$ <br /> Amount of materials needed; <br /> Sand--165 yds. 230 tons Ave. Depth--1.7$ <br /> Rock-- 16 yds 23 tons -- 1.0$ <br /> Sandy Loam-- 30 yds. --- 1.0$ <br /> Topsoil -- 85 yds. --- 9 -- 12 inches <br /> *The above amounts could vary by plus or minus 10%. <br />
The URL can be used to link to this page
Your browser does not support the video tag.