My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1999-011851 - new septic system
Orono
>
Property Files
>
Street Address
>
W
>
Watertown Road
>
3745 Watertown Road - 32-118-23-34-0012
>
Septic
>
1999-011851 - new septic system
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 4:40:58 PM
Creation date
10/21/2019 2:14:52 PM
Metadata
Fields
Template:
x Address Old
House Number
3745
Street Name
Watertown
Street Type
Road
Address
3745 Watertown Road
Document Type
Septic
PIN
3211823340012
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
25
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
PUMP SELECTION PROCEDURE <br /> A. Determine pump capacity: <br /> Gravity Distribution <br /> 1. Minimum suggested is 20 gpm <br /> 2. Maximum suggested is 45 gpm <br /> t Pressure Distibution <br /> 3. a. Select number of perforated laterals Perforation Discharges in GPM <br /> b. Select perforation spacing= feet. Head Perforation diameter <br /> c. Subtract 2 ft. from the rock layer length. feet (inches) <br /> K...l IAycr Icngth <br /> -2 ft.= feet. 7/32 1/4 <br /> d. Determine the number of spaces between perforations. 1.0a 0.56 0.74 <br /> Length perf.spacing= ft.r ft.= spaces i 1.5 0.69 0.902.Ob 0.80 1.04 <br /> e. spaces+ 1 = _perforations/lateral a Use l.o foot single homes. <br /> f. Multiply perforations per lateral by number of laterals to ' b Use 2.0 feet for anything else. <br /> get total number of perforations. CfA , x 7,r.7== perforations. <br /> b' QTR ;Pr. 1m <br /> gpm. <br /> SELECTED PUMP CAPACITY 3pgpm <br /> $oil Ur atmcnt <br /> 13. Determine head requirements: <br /> 1. Elevation difference between pump and point of discharge. <br /> feet Total pipe length <br /> 2. if pumping to a pressure distribution system,five feet for pressure _a 11 <br /> required at manifold if gravity s sem,Zero. Inlet OG Elevation Ddferunce <br /> feet pipe o S <br /> 3. friction loss <br /> a. Enter friction loss table with gpm and pipe diameter. ... <br /> i►t ------------------------------------- <br /> G �P• Read friction loss i1 feet per 100 feet from table(F-14). <br /> F.L. = / 5 ft./100 ft of pipe <br /> b. Determine total pipe length from pump to discharge ; Friction Loss in Plastic Pipe <br /> point. Estimate by adding 25 percent to pipe length for fitting Nominal <br /> loss,or use a fitting loss chart(F-15 feet). ; pipe dia. <br /> Equivalent pipe length- 1.25 times pipength= Flow Rate 15" 2" 3" <br /> I O x 1.25= '.Z feet gpm <br /> Calculate total friction loss by multiplying <br /> friction loss in ft/100 ft by equivalent pipe length. 20 2.47 0.73 0.11 <br /> Total friction loss= Z 25- x /• Yee +100= 3• feet 25 3.73 1.11 0.16 <br /> 30 5.23 1.55 0.23 <br /> 4. Total head required is the sum of elevation difference, 35 6.96 2.06 0.30 <br /> special head requirements,and total friction loss. 40 8.91 2.6.1 0.39 <br /> 45 11.07 3.28 0.48 <br /> 3, 50 13.46 3.99 0.58 <br /> ,5- + 5 + - 55 4.76 0.70 <br /> (1) (2) (30 1 60 5.60 O.b2 <br /> 65 6.48 0.9E <br /> TOTAL HEAD feet 70 7.41 1.0c <br /> C. Pump selection <br /> 1. A pump must be selected to deliver at least <br /> 3o gpm (Step A) with at least 13..E feet of total head (Step B). <br />