r^.r A <br /> City of Orono Septic System Approval <br /> ISTS DESIGN <br /> YES NO NA <br /> ISTS design specifications shall include proposed flows or other sizing information,minimum sewage tank <br /> capacity, minimum soil treatment area requirements,a plan of the component layout and all other information <br /> necessary to assure the City that the ISTS is designed and will be constructed to receive,treat and dispose of all <br /> of the sewage from the building served. <br /> Setbacks <br /> Feature Sewage Tank(feet) Soil Treatment Area(feet) <br /> Deep well 50 50 <br /> Wetland 50 50 <br /> - General Development Lake 75 75 <br /> —, Recreational Development Lake 75 75 <br /> Natural Environment Lake 150 150 <br /> Tributaries/Streams 75 75 <br /> Driveways,sidewalks,decks and other hardcover 10 10 <br /> Property lines, buildings and buried pipes 10 20 <br /> i Lawn sprinkler systems 10 10 <br /> Sewage Tanks. <br /> Number of Bedrooms Tanks Liquid Capacities(gallons) <br /> 4 or less 1,000+ 1,000 regardless of garbage disposal use <br /> 5 or 6 1,250+ 1,000 regardless of garbage disposal use <br /> / 7, 8 or 9 1,500+ 1,500 regardless of garbage disposal use <br /> l 10 or more Sewage tanks shall be sized as other establishments per MN Rules 7080. <br /> Pumping Stations. <br /> In order to standardize installation and electrical connection methods,the following pumping station requirements <br /> must be met in addition to MN Rules chapter 7080 <br /> Electrical connection: <br /> A watertight,lockable electrical box must be mounted on a four-inch by four-inch treated redwood or cedar post. <br /> All electrical connections shall be made within the box. Pump connection must not be made using a direct line <br /> (plug-in only). Wire entry to the electrical box shall be sealed with a watertight material such as foam or putty. <br /> / Alarm and pump floats shall be on separate electrical circuits. <br /> Electrical wire from the power supply must not run over any tanks and must be laid beside the tanks and placed in <br /> conduit along the electrical post. <br /> Electrical cords from the pump and floats must be run through a two-inch PVC(or equivalent)conduit(schedule <br /> 80)with a one-inch gap between the conduit and the electrical box. Electrical cords must not run through or under <br /> the manhole cover. Wires must not have ground contact. <br /> Pumping Chamber: <br /> Pressure pipe exiting the pumping chamber must be laid on a uniform slope up to the soil treatment area for <br /> proper drain back. The pressure pipe must be sleeved and inside a larger diameter pipe for additional support if <br /> spanning ground that has been excavated. If the pipe at the tank must be lower than union to get elevation for <br /> drain back,a one-quarter inch weep hole must be used. <br /> When soil depths above the pressure distribution pipe is less than 3'/2 feet,insulation must be added to achieve <br /> an insulating factor equal to 3'h feet of soil to decrease the potential for freezing(Styrofoam or concentric piping <br /> are acceptable methods). Piping under hardcover, such as tennis courts or driveways shall be insulated pipe or <br /> equivalent. <br /> A reserve capacity equaling 75%of the anticipated daily flow must be allowed into the pumping chamber between <br /> the alarm activation level and the pump tank inlet. <br /> Protection of drainfield area. <br /> Proposed drainfield areas shall be identified and marked off on the lot at the time of the site evaluation and prior to <br /> any construction or grading occurring in the area. The drainfield area shall remain undisturbed until drainfield <br /> construction is commenced. No vehicular traffic shall be allowed in the drainfield area either before or after <br /> drainfield installation. <br /> ACCEPTED � DENIED by the Metro West on behalf of the City of Orono subject to existing regulations and the <br /> following conditions: /�' <br /> /eSCly.._�.+....Q 4l,2At... J <br /> / <br /> � c tisiMLA—mg- <br /> Inspections required: <br /> 1. 7`'Q A+KS sre ( 1/A-k, +e..L o.e� 5. <br /> 2. /Qor91( --eft 6. <br /> 3. 3-A-4-el, k oop <br /> -I fa, 1.1"c( 7. <br /> 4.F a4- v / 4- A— -It7 7r iw.t f 8. <br /> Lr0y2C�q� ea / <br /> Printed Name: �i &( G'k.) /`O /L,vAr.) Date: 0//6' <br /> w:\septic\septic system approval revised 2-2015.docx <br /> Page 2 of 2 <br />