Laserfiche WebLink
' I *011. <br /> OSTP Pressure Distribution UNIVERSITY <br /> Minnesota Pollution Design Worksheet OF MINNESOTA `_ 1 +`., <br /> Control Agency �`��- <br /> 12. Select Type of Manifold Connection (End or Center): 0 End ❑ Center <br /> 13. Select Loteral Diameter: 2.00 in Table II <br /> Volume of Liquid in <br /> 14. Volume of Liquid Per Foot of Distribution Piping: 0.170 Gallons/ft Pipe <br /> Pipe Liquid <br /> 15. Volume of Distribution Piping = Diameter Per Foot <br /> = [Number of Perforated Laterals (Line 1)X Length of Laterals (Line 4)X (inches) (Gallons) <br /> (Volume of Liquid Per Foot of Distribution Piping(Line 14)] 1 0.045 <br /> 3 X 61 ft X 0.170 gal/ft = 31.1 Gallons 1.25 0. <br /> 1.5 0.1100 <br /> 16. Minimum Dose=Volume of Distribution Piping(Line 15)X 4 2 0.170 <br /> 3 0.380 <br /> 31.1 gals X 4 = 124.4 Gallons 4 0.661 <br /> manifold pipecleanouts .. <br /> J _ <br /> Manifold pipe, J <br /> `� pipe from pump .i <br /> Clean outs ' • �..0' �` >` Altern <br /> ate location <br /> •` ` of pipe from pump <br /> • <br /> 1.00' alternate location <br /> of pipe from pump ‘..' Pipe from pump_ <br /> Comments/Special Design Considerations: <br />