Laserfiche WebLink
New Construction Energy Code Compliance Certificate <br /> Per N 1101.8 Building Certificate.A building certificate shall be posted in a permanently visible location inside Date Certificate Posted <br /> the building. The certificate shall be completed by the builder and shall list information and values of <br /> components listed in Table N1101.8. 1 1/20/15 <br /> Mailing Address of the Dwelling or Dwelling Unit City <br /> 3445 WATERTOWN ROAD ORONO <br /> Name of Residential Contractor MN License Number <br /> GORDON JAMES CONSTRUCTION BC531961 <br /> THERMAL ENVELOPE RADON SYSTEM <br /> Type:Check All That Apply X Passive(No Fan) <br /> o a <br /> c <br /> TActive(With fan and monometer or <br /> other system monitoring deviceCd <br /> ) <br /> 0' ¢ o U U b a <br /> O <br /> Z F C, v <br /> Location a U O y W <br /> Insulation Locaon x 'C* o 1 ;o -0 <br /> «° v d d <br /> ro c an Su <br /> E° S Z w Ci v° uo g; rx Other Please Describe Here <br /> Below Entire Slab --- X <br /> Foundation Wall R-5 X Exterior w/Waterproofng <br /> Perimeter of Slab on Grade X <br /> Rim Joist Foundation 2 1/4"Thick X Type in location:interior exterior or integral <br /> Rim Joist 19f Floor+ 2 1/4"Thick X Type in location:interior exterior or integral <br /> Wall R-19 X <br /> Ceiling,flat R-44 X <br /> Ceiling,vaulted R-44 X <br /> Bay Windows or cantilevered areas R-34 X <br /> Bonus room over garage N/A <br /> Describe other insulated areas <br /> Windows&Doors Heating or Cooling Ducts Outside Conditioned Spaces <br /> Average U-Factor excludes skylights and one door U: 0.29 Not applicable,all ducts located in conditioned space <br /> Solar Heat Gain Coefficient(SHGC): 0.30 R-value <br /> MECHANICAL SYSTEMS Make-up Air Select a Type <br /> Appliances Heating System Domestic Water Heater Cooling System X Not required per mech.code <br /> FuelType Geothermal Natural Gas Geothermal Passive <br /> Manufacturer GeoComfort Rheem GeoComfort Powered <br /> Interlocked with exhaust device. <br /> Model GXT060-GWT036 42VP75FW GXT060 Describe: <br /> Input inCapacity in �� Output in 60000 Other,describe: <br /> Rating100000 or Size BTUS: Gallons: Tons: <br /> Heat Loss: 98635 Heat 47098 Location of duct or system: <br /> Structure's Calculated Gain: <br /> AFUE or SEER: 20 EER <br /> HSPF% 4.0 COP <br /> Calculated 51021 <br /> Efficiency cooling load: Urn's <br /> "round duct OR <br /> Mechanical Ventilation System "metal duct <br /> Describe any additional or combined heating or cooling systems if installed:(e.g.two furnaces or air Combustion Air Select a Type <br /> source heat pump with gas back-up furnace): Not required per mech.code <br /> Select Tvve X Passive <br /> X Heat Recover Ventilator(HRV) Capacity in cfms: Low: 80 High: 183 Other,describe: <br /> Energy Recover Ventilator ERV Capacity in cfms: Low: Hi h: Location of duct or system: <br /> Continuous exhaustin fans rated capacity in cfms: MECHANICAL ROOM <br /> Location of fan(s),describe: I Bathrooms Laundry Room&Vent Hood 80 Cfm's <br /> Capacity continuous ventilation rate in cfms: 6 "round duct OR <br /> Total ventilation intermittent+continuous rate in cfms: "metal duct <br /> Created by BAM version 052009 <br />