My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2015-00555 - new mound system
Orono
>
Property Files
>
Street Address
>
W
>
Watertown Road
>
3445 Watertown Road - 32-118-23-43-0009
>
Septic
>
2015-00555 - new mound system
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 4:41:38 PM
Creation date
10/7/2019 1:18:33 PM
Metadata
Fields
Template:
x Address Old
House Number
3445
Street Name
Watertown
Street Type
Road
Address
3445 Watertown Road
Document Type
Septic
PIN
3211823430009
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
34
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
OSTP Design Summary Worksheet UNIVERSITY �n <br /> Minnesota Pollution OF MINNESOTA w� <br /> Control Agency <br /> Property Owner/Client: Gordon James Construction Project ID: v 06.12.13 <br /> Site Address:13445 Watertown Road,Orono,Hennepin County(Primary) Date: 1/19/15 <br /> 1. DESIGN FLOW AND TANKS <br /> A. Design Flow: 750 Gallons Per Day(GPD) Note: The estimated design flow is considered a peak flow rate <br /> including a safety factor.For long term performance,the average <br /> B. Septic Tanks: daily flow is recommended to be<60%of this value. <br /> Minimum Code Required Septic Tank Capacity: 2250 Gallons,in Tanks or Compartments <br /> Recommended Septic Tank Capacity: 2250 Gallons,in Tanks or Compartments <br /> Effluent Screen: No Alarm; No <br /> C. Holding Tanks Only: <br /> Minimum Code Required Capacity: Gallons,in Tanks <br /> Designer Recommended Capacity: Gallons,in Tanks <br /> Type of High Level Alarm: <br /> D. Pump Tank 1 Capacity(Code Minimum): Gallons Pump Tank 2 Capacity(Code Minimum): Gallons <br /> Pump Tank 1 Capacity(Designer Rec): Gallons Pump Tank 2 Capacity(Designer Rec): Gallons <br /> Pump 1 1 36.0 GPM Total Head 34.3 ft Pump 2GPM Total Head It <br /> Supply Pipe Dia. 2.00 in Dose Volume:E:::=gaL Supply Pipe Dia.[==in Dose Volume: gal <br /> 2. SYSTEM TYPE <br /> Type of Soil Treatment and Dispersal Meas <br /> Q Trench O Bed *Lard r O Gravity Distrbution QQ Pressure Di vel O Fressrre Dislrbutionllnlevel <br /> O Drip O Holding rank O At-Grade 'Selection Required Benchmark Elevation: Sea Level ft <br /> Benchmark Location- <br /> System Type Type of Distribution Media: <br /> ❑Type I ❑Type 11 Type ill []Type IV ❑Type V 0 Drakrffeld Rods ❑Regmered Treawwrt Media: <br /> 3. SITE EVALUATION: <br /> A. Depth to Limiting Layer: 22 in 1.8 ft B. Measured Land Slope%:1 3.0 % <br /> C. Elevation of Limiting Layer:1 1041.3 D. Soil Texture: —Clay Loam <br /> E. Loc.of Restricive Elevation: F. Soil Hyd.Loading Rate: 0.45 GPD/ftZ <br /> G. Minimum Required Separation: 36 in 3.0 1 ft H. Perc Rate: 9.6 MPI <br /> 1. Code Maximum Depth of System: Mound in Comments: Remove fill <br /> 4. DESIGN SUMMARY <br /> Trench Design Summary <br /> Dispersal Area ft2 Sidewall Depthin Trench Widthin <br /> Total Lineal Feetft Number of Trenches Code Maximum Trench Depthin <br /> Contour Loading RateE=ft Designer's Max Trench DepthE:=in <br /> Bed Des( n Summary <br /> Absorption Areaft2 Media Below Pipein Code Maximum Bed Depthin <br /> Bed WidthE=ft Bed Length==ft Designer's Max Bed DepthE=in <br />