My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2015-00555 - new mound system
Orono
>
Property Files
>
Street Address
>
W
>
Watertown Road
>
3445 Watertown Road - 32-118-23-43-0009
>
Septic
>
2015-00555 - new mound system
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 4:41:38 PM
Creation date
10/7/2019 1:18:33 PM
Metadata
Fields
Template:
x Address Old
House Number
3445
Street Name
Watertown
Street Type
Road
Address
3445 Watertown Road
Document Type
Septic
PIN
3211823430009
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
34
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
OSTP Basic Pump Selection Design UNIVERSITYFU <br /> s <br /> Minnesota Pollution Worksheet OF MINNESOTA <br /> Control Agency <br /> 1. PUMP CAPACITY Project ID: v 06.12.13 <br /> Pumping to Gravity or Pressure Distribution: Q Gravity Q Pressure Selection required <br /> 1. If pumping to gravity enter the gallon per minute of the pump: GPM (10-45 gpm) <br /> 2. If pumping to a pressurized distribution system: 36.0 GPM <br /> 3. Enter pump description: <br /> tree t symem <br /> 2. HEAD REQUIREMENTS S point of discharge <br /> ,m <br /> A. Elevation Difference 20 ft �nao <br /> between pump and point of discharge: ' <br /> rdet fW Elevation%,- <br /> B. Distribution Head Loss: ft -- dfference <br /> C. Additional Head Loss: ft(due to special equipment,etc.) ----------------------------- -------------- <br /> Table <br /> ------------Table I.Friction Loss in Plastic Pipe per 100ft <br /> Distribution Head Loss <br /> Gravity Distribution = Oft Flow Rate Pi a Diameter(inches) <br /> (GPM) 1 1.25 __1.5 2 <br /> Pressure Distribution based on Minimum Average Head 10 9.1 3.1 1.3 0.3 <br /> Value on Pressure Distribution Worksheet: 12 12.8 4.3 1.8 0.4 <br /> Minimum AveraCle Head Distribution Head Loss 1 14 17.0 5.7 2.4 0.6 <br /> 1ft Sft 16 21.8 7.3 3.0 0.7 <br /> 2ft 6ft 18 9.1 3.8 0.9 <br /> 5ft 1 Oft 20 11.1 4.6 1.1 <br /> 25 16.8 6.9 1.7 <br /> D. 1.Supply Pipe Diameter: 2.0 in 30 23.5 9.7 2.4 <br /> 35 12.9 3.2 <br /> 2.Supply Pipe Length: 225 ft 40 16.5 4.1 <br /> E. Friction Loss in Plastic Pipe per 100ft from Table I: 45 20.5 5.0 <br /> 50 6.1 <br /> Friction Loss= 3.32 ft per 10Dft of pipe 55 7.3 <br /> 60 8.6 <br /> F. Determine Equivalent pipe Length from pump discharge to soil dispersal area discharge 65 I 10.0 <br /> point. Estimate by adding 25%to supply pipe length for fitting loss. Supply Pipe Length 70 11.4 <br /> (D.2) X 1.25=Equivalent Pipe Length 75 13.0 <br /> 225 <br /> 85 16.4 <br /> ft X 1.25 = 281.3 ft <br /> 95 20.1 <br /> G. Calculate Supply Friction Loss by multiplying Friction Loss Per 100ft (Line E)by the Equivalent Pipe Length (Line F)and divide by 100. <br /> Supply Friction Loss= <br /> 3.32ft <br /> per 100ft X 281.3 ft 100 = 9.3 ft <br /> H. Total Head requirement is the sum of the Elevation Difference (Line A),the Distribution Head Loss(Line B),Additional Head Loss(Line C),and the <br /> Supply Friction Loss(Line G ) <br /> 20.0 ft + 5.0 ft + E==ft + 9.3 ft 34.3 ft <br /> 3. PUMP SELECTION <br /> A pump must be selected to deliver at least 36.0 GPM(Line 1 or Line 2)with at least 34.3 feet of total head. <br /> Comments: <br />
The URL can be used to link to this page
Your browser does not support the video tag.