Laserfiche WebLink
CITY OF ORONO 56 6124730510 05/18/98 15:35 15 :04/05 NO:816 <br /> 1YJ111Ue Ulii 1uuuLtiuli %A/W.1 lit F gcuul <br /> Qai Notification of Intent to Perform a Demolition <br /> "411111111111101*r Type of Notification ( 1 Original O Amended [ }Project Cancellation <br /> f etnolitipn Cgntrgort Bu#lfline Tpformationz <br /> Name: __ Building Name: <br /> Address; Address/Location: <br /> City,State,Zip: <br /> City,State,Zip. _ County; <br /> Contact Person: Phone Number(s): <br /> Phone Number(s): Age of Bldg.(years): Size of Bldg.(sq.ft.): <br /> Number of Floors Including Basement Level(s): <br /> Building Owner: Present UseofBldg.: <br /> Name: meati s 1) . r< Prior Use of Bldg.: <br /> Address: S 12A t=1A`Vtot ..7-174.4s-41.0 <br /> Dates when demolition or intentional burning <br /> will Begin &End <br /> City,State,Zip: t=t1 i't's '0") Sys Notification must be postmarked or received ten(10)working days <br /> Contact person: S ci#04_ _ before demolition begins. 'See item 15 for emergency demolitions. <br /> PhoneNumber(s): y�- /S S S� Both Beginning and Ending dates should be amended in writing es <br /> necessary to reflect current project dates_ <br /> If there is>260 linear feet or>160 square feet of Regulated Asbestos-Containing Material (RACM) in the building <br /> to be demolished, it must be removed by a licensed asbestos contractor prior to demolition. The State of IYENT- <br /> Notice of Intent to Perform an Asbestos Abatement Project must be used to notify for the asbestos removal. <br /> Is nonfrlable ACM present in the structure to be demolished ? [ ] YES [ 1 NO <br /> If YES complete items 1-9. If NO complete items 3-9. <br /> 1. If ACM will be left in place for the demolition indicate the amount of Category I and/or Category II <br /> nonfrlable ACM left in place. <br /> Cates.I Linear Feet Categ.iI Linear Feet <br /> Square Feet Square Feet <br /> Cubic Feet Cubic Feet <br /> ir.� tiez iJ•'•%C�`+afr i'i_LZ.11 ..4. it ..,�i'•.'1&°s 1i 6''+z+."'&means any material,excluding <br /> gaskets,resilient floor covering,and asphalt roofing products Category I nonfriable ACM,containing more than one percent <br /> containing more than one percent asbestos. asbestos that,when dry,cannot be crumbled,pulverized,or <br /> *Category I nonfrlable ACM is not allowed to remain In place reduced to a powder by hand pressure. <br /> for demolition if It is In poor condition. *Category II nonfrlable ACM is not allowed to remain In place <br /> for demolition if It has a high probability of becoming crumbled. <br /> pulverized,or reduced to a powder during demolition,transport, <br /> or disposal. (az transite,cement,slate roofing) <br /> 2. Description & Location of ACM remaining in place(including floor#and room #): <br /> • <br /> RECEIVED TIME MAY. 19. 3:35AM <br />