0 "' o <br /> 17X4CITY of ORONO <br /> Municipal Offices <br /> T � � Gti <br /> Street Address: Mailing Address: <br /> '9ltHpg' 2150 Kelley Parkway P.O. Box 66 <br /> Orono, MN 55356 Crystal Bay, MN 55323.0066 <br /> Owner: d Address: 3400 Watertown Rd. <br /> Permit #'s: 7603 Dates: 9/6/84 Contractors: Marty's Exc. <br /> (This is XI an existing system [ ] new construction) . <br /> SYSTEM COMPLIANCE (1-3) : 1 <br /> Code System: Meets or exceeds current City standards in all respects relating to design, <br /> 0construction, and location. Appears to be operating properly. <br /> 2 Compliant System: Does not meet all current City standards for new construction, but in <br /> most respects appears to be designed, located, and constructed in accordance with previous <br /> codes and is functioning properly. <br /> 3 Non-Compliant System: System may or may not meet current City standards for design, <br /> construction, or location, but is failing to properly treat and dispose of the current <br /> input; and any system with less than three feet of vertical separation between the bottom of <br /> the drainfield and the saturated soil level. <br /> (The saturated soil level [ ] has or [ ] has not been identified at this time. If the <br /> saturated soil level has notLbe identified, this classification is subject to revision.) <br /> TANK CONDITION (5-9) : 9 <br /> 5 Pumpout not needed at this time. <br /> 6 Solids accumulation in tanks indicates .they should be pumped out this year. <br /> 7 System is discharging to the surface. Tanks must be pumped out within 48 hours. <br /> 8 Inspection risers missing-tanks could not be inspected. If tanks have not been pumped out <br /> within three years, they should be pumped out and risers installed now. <br /> Inspection pipe is located over tank baffle-can not measure solids accumulation. If tanks <br /> have not been pumped out within three years, they should be pumped out now. <br /> (During the last septic tank Maintenance Pumpout the tanks [ J were or 'WIJ were not confirmed <br /> to be watertight by the licensed pumping contractor. If the tanks were not confirmed to be <br /> watertight, this classification is subject to revision.) <br /> PZATNFTELn CONDITION (11-14) : 11 <br /> 0 Drainfield is dry, no surfacing evident. <br /> 12 Some evidence of surfacing, not critical yet. Repair is not required at this time. <br /> 13 Drainfield is saturated and visibly discharging untreated effluent to the surface. Contact <br /> the City Inspector immediately. Repair must be completed within 90 days. <br /> 14 Drainfield extent and condition unknown. <br /> POTENTIAL FOR SYSTEM FAILURE& (system age and condition. soils. etc.) : low <br /> COMMENTS: <br /> i <br /> Date of Inspection S ptic System Inspector <br /> Note: In the event that this inspection report is used to satisfy the requirements for a <br /> transfer of property, this report does not guarantee that an existing system will continue to <br /> function properly, but indicate,, tploo a if*39fi 0 s{ stec�7L}r % current conditions. <br />