Laserfiche WebLink
OSTP Pressure Distribution <br /> UNIVERSITY <br /> Minnesota Pollution Design Worksheet OF MINNESOTA <br /> Control Agency <br /> f <br /> 12. Select Type of Manifold Connection (End or Center): F11 end ❑ center <br /> 13. Select Lateral Diameter: 1.50 in ! Table 11 <br /> Volume of Liquid in <br /> 14. Volume of Liquid Per Foot of Distribution Piping: 0.110 Gallons/ft Pipe <br /> 15. Volume of Distribution Piping = Pipe Liquid <br /> Diameter Per Foot <br /> _[Number of Perforated Laterals (Line 1)X Length of Laterals (Line 4)X (inches) (Gallons) <br /> (Volume of Liquid Per Foot of Distribution Piping(Line 14)] 1 0.045 <br /> X 36 ft X 0.110 gat/ft = 11.9 Gatlons 1.25 0.078 <br /> 1.5 0.110 <br /> 16. Minimum Dose=Volume of Distribution Piping(Line 15)X 4 2 0.170 <br /> 3 0.380 <br /> 11.9 gals X 4 = 47.5 Gallons 4 0.661 <br /> manitold pipe` Cleanouts ------- <br /> Manifold <br /> ---Manifold pipe, <br /> pipe from pump , <br /> Jean outs --`'--_ <br /> Alternate location <br /> • of pipe from pump <br /> alternate location <br /> of pipe from purnli Pipe from pump <br /> Comments/Special Design Considerations: <br />