09-03-2019 Septic Compliance Inspection
Orono
>
Property Files
>
Street Address
>
T
>
Truffula Trail
>
200 Truffula Trail - 33-118-23-44-0039
>
Septic
>
09-03-2019 Septic Compliance Inspection
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 4:53:09 PM
Creation date
9/24/2019 10:38:41 AM
Metadata
Fields
Template:
x Address Old
House Number
200
Street Name
Truffula
Street Type
Trail
Address
200 Truffula Trail
Document Type
Septic
PIN
3311823440039
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
8
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
, Property address: 2,10D ,11' Inspector initials/Date: ` l��l l `•�-'�-19 <br /> 4. Soil Separation—Compliance component#4 of 5 <br /> Date of installation: `7 )"")cY ❑Unknown Verification method(s): <br /> ShoreandNVelihead protectioMFood Beverage ElYes ®No Soil observation does not expire. Previous soil <br /> Lodging? <br /> observations by two independent parties are sufficient, <br /> Compliance criteria: unless site conditions have been altered or local <br /> For systems built prior to April 1, 1996,and 0 Yes 0 No requirements difiSer. <br /> not located in Shoreland or Wellhead ® Conducted soil observation(s) (Attach boring logs) <br /> Protection Area or not serving a food, <br /> beverage or lodging establishment: ❑ Two previous verifications (Attach boring logs) <br /> ❑ Not applicable(Holding tank(s),no drainfield) <br /> Drainfield has at least a two-foot vertical 0 Unable to verify (See Comments/Explanation) <br /> separation distance from periodically <br /> saturated soil or bedrock. 0 Other(See Comments/Explanation) <br /> Non-performance systems built April 1, i Yes 0 No Comments/Explanation: <br /> 1996, or later or for non-performance <br /> systems located in Shoreland or Wellhead <br /> Protection Areas or serving a food, <br /> beverage, or lodging establishment: <br /> Drainfield has a three-foot vertical <br /> separation distance from periodically <br /> saturated soil or bedrock.* <br /> 'Experimental", `Other", or `Performance" 0 Yes 0 No indicate depths of elevations <br /> systems built under pre-2008 Rules; Type iif •s o <br /> or V systems built under 2008 Rules(7080. A. Bottom of distribution media v•-•\i > >'54-1.5- ---; <br /> 2350 or 7080.2400 (Advanced Inspector tw r I. a•s' <br /> License required) B. Periodically saturated soil/bedrock 'a A.3 <br /> Drainfield meets the designed vertical 5-6,414 v.o' <br /> separation distance from periodically C. System separation 5y. _s y3.11 <br /> saturated soil or bedrock. D. Required compliance separation' <br /> Any "no"answer above indicates the system Is- *May be reduced up to 15 percent if allowed by Local <br /> Failing to Protect Groundwater. Ordinance. <br /> 5. Operating Permit and Nitrogen BMP*-Compliance component#5 of 5 Not applicable <br /> . Is the system operated under an Operating Permit? 0 Yes 0 No If"yes",A below Is required <br /> Is the system required to employ a Nitrogen BMP?• 0 Yes 0 No If"yes", B below Is required <br /> BMP--Best Management Practices)specified in the system design <br /> if the answer to both questions is "no",this section does not need to be completed. <br /> Compliance criteria <br /> a. Operating Permit number: <br /> Have the Operating Permit requirements been met?Have © No <br /> b. Is the required nitrogen BMP in place and properly functioning? ❑Yes ❑ No <br /> Any"no"answer indicates Noncompliance, <br /> Upgrade Requirements(Minn. Stat.§116.55)An imminent threat to public health and safely(ITPHS)must be upgraded,replaced, or its use <br /> discontinued within tan months of receipt of this notice or within a shorterperiod if required by local ordinance.if the system is failing to protect <br /> ground water,the system must be upgraded,replaced,or its use discontinued within the time required by local ordinance. if en existing system <br /> Is not falling as defined in law,end has at least two feet of design soil separation,then the system need not be upgraded,repaired,replaced, or <br /> its use discontinued,notwithstanding any local ordinance that is mom strict This provision does not apply to systems in shoreland areas, <br /> Wellhead Protection Areas, or those used in connection with food,beverage,and lodging establishments as defined in law. <br /> w N4.pca.state.Clln.us • 651.296.6300 9 BOO 657.3B64 s TTY 651.2B2..5332 or BOO. 573864 0 Available in alternative formats <br />