Laserfiche WebLink
Once the iron filter has been removed & the drainage diverted away, the system <br /> could be monitored quarterly for 2 years to see if the system will recover & the <br /> system could be re-evaluated & made compliant. <br /> For the sale of the home, the replacement cost would need to be put into an escrow <br /> account. <br /> An alternate site for a new system has been identified. 3 soil borings were <br /> completed. A design has not been completed at this time. <br /> The tank report was received on 9-3-19. The tanks were pumped by Kothrade Sewer <br /> , Water & Excavating & were found to be compliant. The manhole riser on the pump <br /> tank should have 10" added to the riser. <br /> Nothing other than gray water (laundry, showers etc.) human waste & toilet tissue <br /> should be disposed of into the septic tanks. Garbage disposals are not <br /> recommended due to adding more solids & fine solids passing through into the <br /> system. Iron filters are also not recommended & should be diverted out of the <br /> system. Excessive amounts of soaps, antibacterial soaps, cleaning agents, shower <br /> cleaners used every shower & chlorine agents may <br /> kill the bacteria you need living in the system. Additives are not recommended. <br /> Recommend to pump & clean you tanks through the manhole by a certified pumper <br /> every 2 years. Check with your pumper to set up a schedule. <br /> Steven B. Schirmers <br />