Watertown Road
>
3310 Watertown Road - 32-118-23-44-0015
>
Permits/Inspections
>
2016-00680 - addn/remodel/repair
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 4:42:30 PM
Creation date
8/21/2019 1:44:51 PM
Metadata
Fields
Template:
x Address Old
House Number
3310
Street Name
Watertown
Street Type
Road
Address
3310 Watertown Road
Document Type
Permits/Inspections
PIN
3211823440015
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
11
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
BBC- Reeves HELICAL PIER INSPECTION RECORD 3310 Watertown Rd, Orono, MN <br /> Design Requirements Extensions Pressure <br /> record length) netpsi) <br /> 1 1 -T tri le lead <br /> (Pier Number) Required Allowable Load 2 kips 1 -T extension 900 <br /> 717/2016 Required Ultimate Load 4 kips <br /> (Date Installed) Required Torque 444 ft-lbs <br /> PB <br /> (Installer Initials) Required Pressure 211 psi <br /> 14'total depth <br /> Design Requirements Extensions Pressure <br /> record length) netpsi) <br /> (Pier Number) Required Allowable Load kips <br /> Required Ultimate Load 0 kips <br /> (Date Installed) Required Torque 0 ft-lbs <br /> (Installer Initials) Required Pressure 0 si <br /> Design Requirements ::1 Extensions Pressure <br /> record length) netpsi) <br /> (Pier Number) Required Allowable Load kips <br /> Required Ultimate Load 0 kips <br /> (Date Installed) Required Torque 0 ft-lbs <br /> (Installer Initials) Required Pressure 0 si <br /> Design Requirements Extensions Pressure <br /> record length) netpsi) <br /> (Pier Number) Required Allowable Load kips <br /> Required Ultimate Load 0 kips <br /> (Date Installed) Required Torque 0 ft-lbs <br /> (Installer Initials) Required Pressure 0 si <br /> Pressure is defined as: supply psi-back psi = net psi Ratio of Pressure to Torque: 1:2.1074 <br /> Ratio of Torque in ft-lbs to Ultimate Capacity (Cu) in kips: 1:.009 Safety Factor= 2 <br /> Formula to calculate Ultimate Capacity (Cu) in kips: Cu = Torque (ft-lbs) x.009 <br /> Formula to calculate Allowable Capacity (Ca) in kips: Ca= Cu/Safety Factor of 2 <br />
The URL can be used to link to this page
Your browser does not support the video tag.