Laserfiche WebLink
Aug 12 14 06:15p Joseph Olson 763-498-8290 p.4 <br /> Propertyaddress: 3065 Watertown Road,Orono,MN Inspector initials/Date: J.0.06125114 <br /> 4. Soil Separation—Compliance component#4 of 5 <br /> Date of installation: 11119M ❑Unknown Verification method(s): <br /> ShorelandNYellhead protectiordFood Beverage ❑Yes M No Soil observation does notexpire.Previous soil <br /> Lodging? <br /> observations by two independent parties are sufficient <br /> Compliance criteria: unless site conditions have been altered or local <br /> For systems built prior to April 1, 1996, and E]Yes ®No requirements differ. <br /> not located in Shoreland or Wellhead ® Conducted soil observation(s)(Attach boring logs) <br /> Protection Area or not serving a food, <br /> ❑ Two previous verifications(Attach boring logs) <br /> beverage or lodging establishment: <br /> ❑ Not applicable(Holding tank(s),no drainfreld) <br /> Drainfield has at least a two-foot vertical ❑ Unable to verify(See Comments/Explanation) <br /> separation distance from periodically <br /> saturated soil or bedrock. ❑ Other(See CommenrsJExplanat;on) <br /> Non-performance systems built April 1, [K Yes ❑No Comment&Explanation: <br /> 1996, or later or for non-performance <br /> systems located in Shoreland or Wellhead <br /> Protection Areas or serving a food, <br /> beverage,or lodging establishment. <br /> Drainfield has a three-foot vertical <br /> separation distance from periodmcally <br /> saturated soil or bedrock.' <br /> "Experimental, "Other"or "Performance" ❑Yes ❑ No Indicate depths of elevations <br /> systems built under pre-2008 Rules;Type 1V <br /> or V systems built under 2008 Rules(7080. A. Bottom of distribution media 98.0 <br /> 2350 or 7060.2400 (Advanced Inspector <br /> License required) B. Periodically saturated soillbedrodk 95.3 <br /> Drairdeld meets the designed vertical C_ System separation 2.7 <br /> separation distance from periodically <br /> saturated soil or bedrock. <br /> _ D_ Required compliance separation' 2.6 <br /> Any "no"answer above indicates the system is *May be reduced up to 15 percent if allowed by Local <br /> Failing to Protect Groundwater. Ordinance. <br /> 5. Operating Permit and Nitrogen BMP*—Compliance component#5 of 5 ® Not applicable <br /> Is the system operated under an Operating Permit? ❑Yes ❑No If"yes",A below is required <br /> Is the system required to employ a Nitrogen BMP? ❑Yes ❑No If"yes",B below is required <br /> BMP--Best Management Practice(s)specified in the system design <br /> If the answer to both questions is "no", this section does not need to be completed. <br /> Compliance criteria <br /> a_ Operating Permit number: <br /> No <br /> Have the OperatingPermit o ! C]Yes ❑ <br /> requirements been met. <br /> b. Is the required nitrogen BMP in place and properly functioning? Yes ❑No <br /> Any"no"answer indicates Noncompliance. <br /> Upgrade Requirements(Minn.Stat.§115.55)An imminent threat to public health and safety OTPHS)must be upgraded,replaced,or its use <br /> discorknued within ten months of recefo of this notice or within a shorter period if required by local ordinance.If the system is falling to protect <br /> ground water,the system must be upgraded,replacer!,or its use discontinued within the time required by local ordinance.If an existing system <br /> is not lading as defined in law,and has at least two feet of design soil separation,then the system need not be upgraded,repaired,replaced,or <br /> its use discontinued,notwithstanding any local ordfnence that is more strict_This provision does not apply to systems in shoreland areas, <br /> Wellhead Protecffon Areas,or those used in connection with food,beverage,and lodging establishments as defined in few. <br /> www.pca.state.mn.us • 651-246-6300 800-657-386a TTY 651-282-5332 or 800.657-3864 • Available in alterative formats <br /> wq-wwists4-3t • 1124/11 Page 3 of 3 <br />