CREScheck Software Version 4.4.1 <br /> NJ( Inspection Checklist <br /> Ceilings: <br /> ❑ Ceiling 1:Flat Ceiling or Scissor Truss,R-36.0 cavity insulation <br /> Comments: <br /> Above-Grade Walls: <br /> ❑ Wall 1:Wood Frame,16"o.c.,R-19.0 cavity insulation <br /> Comments: <br /> Windows: <br /> ❑ Window 1:Vinyl Frame:Double Pane with Low-E,U-factor:0.300 <br /> For windows without labeled U-factors,describe features: <br /> #Panes Frame Type Thermal Break? Yes No <br /> Comments: <br /> Doors: <br /> ❑ Door 1:Glass,U-factor:0.300 <br /> Comments: <br /> ❑ Master patio:Glass,U-factor:0.300 <br /> Comments: <br /> Crawl Space Walls: <br /> ❑ Crawlspace:Masonry Block with Empty Cells,4.0'ht/3.5'bg/3.5'ext.insul!0.5'inside bg depth,R-11.0 cavity insulation <br /> Comments: <br /> Exposed earth in unvented crawl space foundations is covered with a continuous vapor retarder(less than or equal to 0.1 perm).All joints <br /> of the vapor retarder are overlapped by 6 inches and are sealed or taped with edges extending at least 6 inches up the stem wall and <br /> securely attached. <br /> Air Leakage: <br /> ❑ Joints(including rim joist junctions),attic access openings,penetrations,and all other such openings in the building envelope that are <br /> sources of air leakage are sealed with caulk,Basketed,weatherstripped or otherwise sealed with an air barrier material,suitable film or <br /> solid material. <br /> ❑ Air barrier and sealing exists on common walls between dwelling units,on exterior walls behind tubs/showers,and in openings between <br /> window/door jambs and framing. <br /> ❑ Recessed lights in the building thermal envelope are 1)type IC rated and ASTM E283 labeled and 2)sealed with a gasket or caulk <br /> between the housing and the interior wall or ceiling covering. <br /> ❑ Access doors separating conditioned from unconditioned space are weather-stripped and insulated(without insulation compression or <br /> damage)to at least the level of insulation on the surrounding surfaces.Where loose fill insulation exists,a baffle or retainer is installed <br /> to maintain insulation application. <br /> ❑ Wood-buming fireplaces have gasketed doors and outdoor combustion air. <br /> Air Sealing and Insulation: <br /> ❑ Building envelope air tightness and insulation installation complies by either 1)a post rough-in blower door test result of less than 7 <br /> ACH at 33.5 psf OR 2)the following items have been satisfied: <br /> (a)Air barriers and thermal barrier:Installed on outside of air-permeable insulation and breaks or joints in the air barrier are filled or <br /> repaired. <br /> (b)Ceiling/attic:Air barrier in any dropped ceiling/soffit is substantially aligned with insulation and any gaps are sealed. <br /> (c)Above-grade walls:Insulation is installed in substantial contact and continuous alignment with the building envelope air barrier. <br /> (d)Floors:Air barrier is installed at any exposed edge of insulation. <br /> (e)Plumbing and wiring:Insulation is placed between outside and pipes.Batt insulation is cut to fit around wiring and plumbing,or <br /> sprayed/blown insulation extends behind piping and wiring. <br /> Project Title: Lori and Rich Gherardi Report date: 05/08/11 <br /> Data filename: C:\Brennan Prop LLC\Watertown\watertown.rck Page 2 of 4 <br />