2011-00401 - new septic
Orono
>
Property Files
>
Street Address
>
W
>
Watertown Road
>
2985 Watertown Road - 04-117-23-21-0001
>
Septic
>
2011-00401 - new septic
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 5:08:19 PM
Creation date
7/24/2019 10:36:51 AM
Metadata
Fields
Template:
x Address Old
House Number
2985
Street Name
Watertown
Street Type
Road
Address
2985 Watertown Rd
Document Type
Septic
PIN
0411723210001
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
38
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
MOUND DESIGN WORKSHEET (For flows up to 1200 gpd) <br /> i' OU14D A <br /> A. FLOW 375 gpd or measured X 1.5 = gpd <br /> B. SEPTIC TANK LIQUID VOLUMES: 2 - 1250's <br /> C. SITE EVALUATION INFORMATION <br /> 1. Depth of clean sand req. 18.00 inches or 1.50 feet <br /> 2. Depth of percolation tests = 12 inches <br /> 3. Perc. Rate 17 mpi <br /> 4. Land Slope 2.0 percent <br /> D. ROCK LAYER DIMENSIONS <br /> 1. Multiply flow rate by 0.83 to obtain required area of rock layer: <br /> 375 gpd X 0.83 sq ft/gpd 311.25 sq. ft. rock area <br /> 2. Select width of rock layer (Max 10' if<120, or max 5' if>120) 10.0 Yeet <br /> 3. Rockbed length (area/width) 311 sq. ft. / 10.0 feet = 33 feet <br /> E. ROCK VOLUME <br /> 1. Multiply rock area by rock depth to get cubic feet of rock: <br /> 311.25 sq. ft X 1.0 = foot = 311 cubic feet <br /> 2. Divide cubic feet by 27 to get cubic yards: <br /> 311 cu. ft. / 27 = 11.5 cubic yards <br /> 3. Multiply cubic yards by 1.4 to get weight of rock �n tons: <br /> 11.5 cu. yd. X 1.4 = 16.1 tons X 10 % = 20.2 ton req'd <br /> F. ADSORPTION WIDTH <br /> 1. Percolation rate in top 12 inches of soil is 17.0 m i <br /> Soil Texture is SILL ISize for Clay Loam <br /> 2. Select allowable soil loading rate from table: 0.45 gpd 1 sq. ft. <br /> PEC RATE MPI SOIL TEXTURE GPD/SQ.FT. RATIO <br /> FASTER>0.1 COARSE SAND1.2(1 1 00 <br /> 0.1 TO 5 SAND 1.20 1.00 <br /> 0.1 TO 5 FINE SAND 0.60 2.00 <br /> 6 TO 15 SANDY LOAM 0.79 1.52 <br /> 16 TO 30 LOAM 0.60 2.00 <br /> 31 TO 45 SILT LOAM 0.50 2.40 <br /> 46 TO 60 CLAY LOAM 0.45 2.67 <br /> 60 TO 120 CLAY 0.24 5.00 <br /> >120 CLAY 0.20 6.00 <br /> 3. Calculate adsorption width ratio by dividing rock layer loading rate <br /> of 1.20 gpd / sq. ft. by allowable soil loading rate: <br /> 1.20 gpd/ sq. divided by 0.45 gpd / sq. ft. equals 2.67 <br /> 4. Multiply adsorption width ratio by rock layer width to get required adsorption width: <br /> 2.67 X 10.0 feet = 27 feet adsorption width <br /> additional feet added. <br />