Laserfiche WebLink
OSTP Pressure Distribution -� <br /> UNIVERSITY <br /> Minnesota Pollution Design Worksheet OF MINNESOTA <br /> Control Agency <br /> 12. Select Type of Manifold Connection (End or Center): ❑ End ❑ center <br /> 13. Select Lateral Diameter: 2.00 in Table 11 <br /> Volume of Liquid in <br /> 14. Volume of Liquid Per Foot of Distribution Piping: 1 0.170 Gallons/ft Pipe <br /> 15. Volume of Distribution Piping = Pipe Liquid <br /> Diameter Per Foot <br /> _[Number of Perforated Laterals (Line 1)X Length of Laterals (Line 4)X (inches) (Gallons) <br /> (Volume of Liquid Per Foot of Distribution Piping(Line 14)] 1 0.045 <br /> X 61 ft X 0.170 gal/ft 31.1 Gallons 1.25 0.078 11 <br /> 1.5 0.110 <br /> 16. Minimum Dose=Volume of Distribution Piping(Line 15)X 4 2 0.170 <br /> 3 0.380 <br /> 31.1 gals X 4 = 124.4 Gallons 4 0.661 <br /> manifold pipe` --cleanouts <br /> r pipe from pump i, Manifold pipe,` <br /> Jean outs <br /> $ Alternate location <br /> • of pipe from pump <br /> from <br /> location <br /> of pipe from pumd Pipe from pump <br /> Comments/Special Design Considerations: <br />