My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1994-006375 - new septic system
Orono
>
Property Files
>
Street Address
>
W
>
Watertown Road
>
2645 Watertown Road - 04-117-23-12-0008
>
Septic
>
1994-006375 - new septic system
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 5:06:48 PM
Creation date
7/22/2019 2:01:03 PM
Metadata
Fields
Template:
x Address Old
House Number
2645
Street Name
Watertown
Street Type
Road
Address
2645 Watertown Rd
Document Type
Septic
PIN
0411723120008
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
24
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
op <br /> S-P TESTING, INC. Steven B. SYhirmers — MPC ert. o.-627 <br /> / 951 Katydid Lane NE • St. Michael, M 553 12) 497-3566 <br /> Decem r 9 3 <br /> Dickey site <br /> bot tL4-;--Block---2 (existing house) <br /> Orono , [Tenn . Co . , MN <br /> This On-Site Sewage Treatment System is Designed o a Type 1 , five <br /> bedroom home in accordance with the Minnesota Po tion Control <br /> Agency Chapter 7080 and local ordinances . <br /> This site has an existing failing trench system with effluent <br /> surface discharging & a seasonally high water table (mottled soil) <br /> less than 36" from the bottom of the trenches . The existing tanks <br /> may be used upon approval by the local Inspector. <br /> The soils on this site are SCS soils mapped - LrC - Lester loam. <br /> A seasonally high water table was located at 24 " to 34" (mottled <br /> soil ) . Due to the seasonally high water table , a Pressurized <br /> Mound System will need to be installed. The bottom of the rock <br /> bed must be located at least 3 ' above the seasonally high water <br /> table . <br /> The soils at a depth of 12" have a percolation rate averaging <br /> 9 . 7 min/inch. <br /> A pumping chamber will need to be installed to lift the effluent <br /> to the treatment area . <br /> The manifold and supply line pipe must have back drainage to the pumping <br /> chamber . The distribution pipes shall have their ends capped. Be sure <br /> the rock and sand fill material are clean. The sod layer below the <br /> entire mounded area must be turned over, just break up the sod , be sure <br /> not to over work . <br /> The power supply and switches must be located outside the manhole and <br /> pumping chamber in a weather proof enclosure . A warning device must <br /> be installed with a light and sound device , this is in case of a pump <br /> failure. Mercury floats are a good method. <br /> All neighboring wells are located greater than 100 ' away from the <br /> proposed treatment area . <br /> r <br /> ` r,ti► � CONT ' D <br /> J J <br />
The URL can be used to link to this page
Your browser does not support the video tag.