Laserfiche WebLink
0 0 <br /> CITYof ORONO <br /> Municipal Offices <br /> G <br /> Street Address: Mailing Address: <br /> E$II 2150 Kelley Parkway P.O. Box 66 <br /> / Orono, MN 55356 Crystal Bay, MN 55323.0066 <br /> Owner: 1 ke, � %� Address: 2325 Watertown Rd. <br /> Permit #'s: 8313 Dates: 8/29/96 Contractors: Widmer Bros. <br /> (This is [x] an existing system [ ] new construction) <br /> YSTEM COMPLIANCE (1-3) :LT 1 <br /> Code System: Meets or exceeds current City standards in all respects relating to design, <br /> construction, and location. Appears to be operating properly. <br /> 2 Compliant System: Does not meet all current City standards for new construction, but in <br /> most respects appears to be designed, located, and constructed in accordance with previous <br /> codes and is functioning properly. <br /> 3 Non-Compliant System: System may or may not meet current City standards for design, <br /> input; and any system with less <br /> construction, or location, but is failing to properly treat and dispose of the current <br /> than three feet of vertical separation between the bottom <br /> of the drainfield and the saturated soil level. <br /> (The saturated soil level [x ] has or [ ] has not been identified at this time. If the <br /> saturated soil level has not been identified, this classification is subject to revision.) <br /> &tlK CONDITION (5-9) : 5 <br /> Pumpout not needed at this time. <br /> 6 Solids accumulation in tanks indicates they should be pumped out this year. <br /> 7 System is discharging to the surface. Tanks must be pumped out within 48 hours. <br /> 8 Inspection risers missing-tanks could not be inspected. If tanks have not been pumped out <br /> within three years, they should be pumped out and risers installed now. <br /> 9 Inspection pipe is located over tank baffle-can not measure solids accumulation. If tanks <br /> have not been pumped out within three years, they should be pumped out now. <br /> (During the last septic tank Maintenance Pumpout the tanks [ i were or 0< <br /> I notto be watertight by the licensed pumping contractor. If the tanks were n ore confirmed coned <br /> tbe <br /> watertight, this classification is subject to revision.) <br /> Qg8INFIELD CONDITION (11-14) : 11 <br /> Drainfield is dry, no surfacing evident. <br /> 2 Some evidence of surfacing, not critical yet. Repair is not required at this time. <br /> 13 Drainfield is saturated and visibly discharging untreated effluent to the surface. <br /> Contact the City Inspector immediately. Repair must be completed within 90 days. <br /> 14 Drainfield extent and condition unknown. <br /> POTENTIAL FOR SYSTEM FAILURE: (system acre and condition, soils, etc.) : low <br /> COMMENTS: <br /> M I?-9? <br /> Date of Inspection <br /> 4SVc System Inspector <br /> Note: In the event that this inspection report is used to satisfy the requirements for a <br /> transfer of property, this report does not guarantee that an existing system will continue to <br /> function properly, but indicates the operation of the system under current conditions. <br /> Telephone (612) 473-7357 0 FAX 473-0510 <br />