My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2018-00435 - indoor pool
Orono
>
Property Files
>
Street Address
>
W
>
Walters Port Lane
>
2709 Walters Port Lane - 21-117-23-23-0060
>
Permits/Inspections
>
2018-00435 - indoor pool
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 4:04:40 PM
Creation date
7/16/2019 12:13:53 PM
Metadata
Fields
Template:
x Address Old
House Number
2709
Street Name
Walters Port
Street Type
Lane
Address
2709 Walters Port Lane
Document Type
Permits/Inspections
PIN
2111723230060
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
88
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
1DOND '00 <br /> TECHNICAL SPECIFICATION NOTES V <br /> ill <br /> GENERAL <br /> 1. POOL ENCLOSURE STRUCTURE HAS BEEN DESIGNED IN CONFORMANCE WITH THE - <br /> IBC 2012/ASCE 7-10 FOR THE LOADING CRITERIA LISTED BELOW. <br /> 2. ALL DIMENSIONS AND DETAILS SHOWN HAVE BEEN OBTAINED FROM PARTIAL DATA&DRAWINGS <br /> SUPPLIED BY CCSI INTERNATIONAL INC.WITH NO SITE SURVEY/VISIT BY MEI. ACTUAL SITE DIMENSIONS <br /> bi SHOULD BE VERIFIED PRIOR TO FABRICATION OF ANY MATERIAL OR FIELD ADJUSTMENT PROVISIONS <br /> SHOULD BE MADE. <br /> 3. THESE DRAWINGS INDICATE THE MAJOR OPERATIONS TO BE PERFORMED,BUT DO NOT SHOW EVERY <br /> FIELD CONDITION THAT MAY BE ENCOUNTERED. THEREFORE,PRIOR TO BEGINNING OF WORK,THE <br /> CONTRACTOR SHOULD SURVEY THE JOB SITE THOROUGHLY TO MINIMIZE FUTURE FIELD PROBLEMS. <br /> CCS1 <br /> 4. ENCLOSURE SHALL BE INSTALLED BY A CONTRACTOR EXPERIENCED IN SIMILAR WORK. CARE SHALL BE <br /> TAKEN IN THE INSTALLATION , ANY AND ALL MEMBERS IN ACCORDANCE WITH RECOGNIZED INDUSTRY INTERNATIONAL, INC• <br /> STANDARDS AND PROCEDURES. ALL APPLICABLE OSHA SAFETY GUIDELINES ARE TO BE FOLLOWED. MEI <br /> IS NOT PROVIDING FIELD INSTALLATION SUPERVISION. /^ <br /> 5. THE FOUNDATION SHALL BE DESIGNED BY OTHERS AS REQUIRED TO WITHSTAND THE LOADS IMPOSED _/ i� 51 n ,e �e/►1� v� <br /> BY THE NEW ENCLOSURE SHOWN ON THE DRAWINGS. {�(, S <br /> 6. THE PLANS AND DETAILS WITHIN DO NOT INCLUDE DETAILS OR DESIGN FOR DRAINAGE OR _/ /� <br /> WATERPROOFING OF EXTERIOR OR INTERIOR SURFACES OF THE BUILDING/STRUCTURE. U /' / /n /// �'^�y ./w RECEIVED <br /> 7. PANELS ARE ATTACHED TO STRUCTURAL MEMBERS WITH STEEL SCREWS AS PER PANELS MANUFACTURER </l ( ax w( (/ (/[ �'(/l <br /> REQUIREMENTS&RECOMMENDATIONS FOR LOADING. ENCLOSURE PANELS ARE TO MEET RATED LOADS /� / MAR 21 2018 <br /> AS PER MANUFACTURER SPECIFICATIONS. ,^ A n I 0 `il' �l/./_ 0(/,5 <br /> B. CONSULT CCSI INTERNATIONAL INC.CONSTRUCTION MANUAL FOR MORE DETAILS. <br /> ROOF PANELS CI OF OF2Q0 <br /> 9. FASTENER HOLES IN ROOF PANELS THAT ARE NOT FACTORY DRILLED AND MUST BE DRILLED IN THE <br /> FIELD. <br /> 10.PANEL FASTENERS#14 TEK S.S.TO BE SPACED MAX.AT 24"O.C.AND AS PER PANELS MANUFACTURER <br /> REQUIREMENTS AT ALL SIDES OF PANELS. <br /> 11.PANELS ARE TO MEET RATED LOADS AS PER MANUFACTURER SPECIFICATIONS. D U N KEY RESIDENCE <br /> STRUCTURAL ALUMINUM & STEEL CODE COMPLIANCE <br /> 12.ALL FABRICATION AND INSTALLATION SHALL BE DONE IN ACCORDANCE WITH THE ALUMINUM ALL WORK SHALL BE PERFORMED AND MATERIAL INSTALLED IN ACCORDANCE <br /> ASSOCIATION"ALUMINUM CONSTRUCTION MANUAL AND SPECIFICATIONS". WITH THE CURRENT EDITIONS OF THE FOLLOWING CODES AS ADOPTED BY THE 2709 WALTERS PORT LN. <br /> LOCAL GOVERNING AUTHORITIES. <br /> 13.ALL ALUMINUM ANGLE,CHANNEL,PIPE AND MISCELLANEOUS MEMBERS SHALL CONFORM TO ASTM 8308 <br /> SPECIFICATIONS ALLOY 6061-T6. CODE: IBC 2012/ASCE?-10 EXCELSIOR, MN SS331 <br /> 14.ALL ALUMINUM PLATE MEMBERS SHALL CONFORM TO ASTM 8209 SPECIFICATIONS-ALLOY 6061-T6. <br /> 15.ALL STEEL BOLTS SHALL BE NEW 1/2"DIAMETER HIGH STRENGTH STAINLESS STEEL 316 BOLTS,BEARING <br /> TYPE'X'(THREADS EXCLUDED), UNLESS NOTED OTHERWISE.USE LOCKNUTS&FLAT WASHERS ON ALL - <br /> BOLTS. LOADING CRITERIA <br /> 9 16.ALL BOLTS SHALL BE TIGHTENED USING TURN-OF-THE-NUT METHOD. LIVE ROOF LIVE LOAD 20 psf <br /> 17.EXPANSION ANCHOR BOLTS AND TEK SCREWS SHALL BE AS CALLED FOR ON PLANS AND AS FLOOR LOAD N/A <br /> MANUFACTURED BY HILTI FASTENING SYSTEMS OR DEWALT ANCHORS OR APPROVED EQUAL. ANCHORS ROOF SNOW:.DAD 50 psf <br /> TO BE INSTALLED IN HOLES DRILLED WITH CARBIDE TIPPED DRILL BITS. INSTALL AND TORQUE BOLTS WIND WIND SPEED 115 MPH(3 SEC.) D RAW I N G INDEX <br /> AS PER MANUFACTURER'S RECOMMENDATIONS. <br /> _ RISK CATEGORY II <br /> 18.EXPANSION ANCHORS ARE TO BE INSTALLED INTO REINFORCED CONCRETE OR SOLID GROUTED BOND EXPOSURE D T01 TITLE SHEET AND TECHNICAL SPECIFICATION NOTES <br /> BEAMS WITH A MINIMUM 28 DAY COMPRESSIVE STRENGTH OF 4,000 PSI. <br /> TOPOGRAPHY FArTOR Kzt=1.00 <br /> 19.ALL WELDING SHALL BE DONE USING 5556 FILLER WIRE ELECTRODES AND IN ACCORDANCE WITH THE IMPORTANCE FACTOR I=1.00 S01 OVERALL STRUCTURAL PLAN VIEW <br /> AMERICAN WELDING SOCIETY(A.W.S.)STANDARDS AND SPECIFICATIONS. <br /> INTERNAL PRESSURE COEFFICIENT GCpi= f0.18 SO2 STRUCTURAL ELEVATION VIEW <br /> 68.38 psf(ROOF) <br /> 0 DESIGN COMPONENTS'?<CLADDING 43.51 psf(WALLS) S03 STRUCTURAL CROSS-SECTION VIEWS <br /> SEISMIC IMPORTANCE FA TOR Ie=1.00 SO4 STRUCTURAL CONNECTION DETAILS <br /> y OCCUPANCY CAI EGORY I <br /> SITECLAS5 "D° S05 STRUCTURAL CONNECTION DETAILS <br /> SPECTRAL RESPONSE Ss=0.05 g <br /> _ RESPONSE MODIF.FACTOR R= 3.5 <br /> "I hereby certify that this plan,specification,or report was prepared <br /> by me or under my direct supervision and that I am a duly Licensed <br /> Professional En ineer under the laws of the State of Minnesota." <br /> E. Mark <br /> License#2#2 <br /> MN License CCSI INTERNATIONAL INC. <br /> ROUE ENGINEERING INiERMO%, INC. 17950 PRESTON ROAD SUITE 720 DUNKLEY RESIDENCE <br /> DALLAS, TEXAS 75252-5635 <br /> (fox: <br /> 972-783-2578 (fox: 2583) TITLE SHEET AND TECHNICAL SPECIFICATION NOTES <br /> � <br /> _ www.maIoufengIneering.com 2709 WALTERS PORT LN. CCS1 L MEI PROJECT ID SHEET NUMBER REV. <br /> ®MQINC 2018 EXCELSIOR, MN 55331 INTERNATIONAL INC. o oz/15/le ISSUED FOR CONSTRUCTION IRS LKN MM <br /> r N0. DATE REVISIONS DRAWNENG'D.APP'D FEB 15, 2018 MN05355B-18V0 T01 0 <br />
The URL can be used to link to this page
Your browser does not support the video tag.