My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2018-00435 - indoor pool
Orono
>
Property Files
>
Street Address
>
W
>
Walters Port Lane
>
2709 Walters Port Lane - 21-117-23-23-0060
>
Permits/Inspections
>
2018-00435 - indoor pool
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 4:04:40 PM
Creation date
7/16/2019 12:13:53 PM
Metadata
Fields
Template:
x Address Old
House Number
2709
Street Name
Walters Port
Street Type
Lane
Address
2709 Walters Port Lane
Document Type
Permits/Inspections
PIN
2111723230060
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
88
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
CITY OF ORONO <br /> ` _�",re^[-t AU,::Ire•st htd�,r.i!U`tc• x. . .. , ;r-. <br /> C "ru.. Iqc.. Y535G .0,4,t ,- <br /> August <br /> August 27,2018 <br /> Paul Vogstrom <br /> DCM Construction <br /> 10231 Beebe Lake Road <br /> Hanover, MN 55341 <br /> RE: Dunkley Addition <br /> 2709 Walters Port Lane <br /> Permit#2017-01586 <br /> We have completed our review of the approved and as constructed plans for the above project and find the following <br /> items must be addressed in writing before the Stop Work order can be lifted. <br /> Provide cross section detailing ledgers for floor system. <br /> a. Engineer analysis of floor system by an engineer registered in the State of Minnesota detailing: <br /> A. Bolt spacing,size,type and embedment. <br /> B. Nuts,washers,size and type. <br /> C. Hanger's type and fasteners used. <br /> D. Ledger materials <br /> Provide flashing details for flat roof and materials being used and fixes from the Truss Company or new <br /> engineering for replacement trusses from manufacturer. <br /> Provide copies of the Braced Wall plans with updated changes to room size in bonus room. <br /> Provide beam sizing for all other openings not called out on current plan submitted. <br /> Call out exterior finishes for addition.What are you using,stone or stone veneer,cedar shingles or shingle <br /> panels? Fascia and exterior trim details materials being used. <br /> Provide engineered correction for the TJI's set directly on the poured concrete walls at walkout side of <br /> basement.Also, provide approval from the TJI manufacturer for the correction or installation documentation <br /> from the manufacturer that the install is correct. <br /> Provide cross section with details of all materials being used,type and sizes.Studs,exterior sheathing,finishes, <br /> insulation,gypsum board,floor sheathing and any other materials being used for construction not mentioned. <br /> Please don't hesitate to call if you have any questions. <br /> Regards, <br /> City of Orono <br /> 4�� �� <br /> Roger Peitso <br /> Building Official <br /> City of Orono <br /> Direct:952-249-4625 <br /> Email: rpeitso@ci.orono.mn.us <br /> Fax:952-249-4616 <br /> Cc:Via email,Jeremy Barnhart, Dustin Reif,Sue Dunkley, Melanie Curtis, and Christine Mattson. <br />