Laserfiche WebLink
V4'& - CITY of ORONO <br /> Municipal Offices <br /> b' e � ► street Address: °ISa-a49-460 o Marlin`Address: <br /> O$' 2750 Kelley Parkway P.O. Box 66 <br /> Orono, MN 55356 Crystal Bey, MN 55323-0066 <br /> To Current Owner: Address: <br /> City Ordinance 199 requires that each existing on-site sewage treatment system in Orono be inspected every two years. <br /> The on-site sewage treatment system at the above address has been inspected and appears to fall into the categories checked below. <br /> YSTEM CONFORMITY 1-3 : <br /> "CODE SYSTEM"An LSTS which meets all the location,design and construction standards of the current Orono Municipal Code. <br /> 2 "COMPLIANT SYSTEM" An ISTs which does not meet all the location,design and construction standards of the current Orono <br /> Municipal Code but does meet the three foot separation requirement or two foot requirement for systems installed 1996 or earlier,and <br /> which is not failing or an imminent threat to public health or safety. <br /> 3 "NON-COMPLIANT SYSTEM" A prohibited ISTS;an ISIS located within a designated 100-year flood plain,any ISTS which may <br /> or may not meet all the location,design,or construction standards of the current Orono Municipal Code and which is failing for any <br /> reason;and any ISIS with less than three feet of unsaturated soil or sand between the distribution device and the limiting soil characteristics. <br /> TANK CONDITION(5-7): <br /> Tank inspection indicates: <br /> !0 Pumpout not needed at this time. <br /> 6 -Septic tanks must be out this year (city code recommends tanks to be pumped out once every 3 years. <br /> Tank was last pumped 7-1\-dy - 1. <br /> Make sure septic-tanks are Pumped-through manhole and not through white inspection Pipes This allows for the proper <br /> cleaning. Keep neater softener and iron filter discharge out of septic system to probng life of drainfield Ask pamper to test <br /> alarm float to verify alarm is still working in your mouse. The alarm warms owner that MBtage is about to backup into basement. <br /> 7 Inspection risers missing-tanks could not be inspected. Inspection risers(4"dia.pipe)must be installed in each tank. If <br /> tanks have not been pumped out within the last three years,they should be pumped out now. <br /> DRAINFMI.D CONDITION(8-10): <br /> Drainfield is dry,no surfacing evident. <br /> 9 Some evidence of surfacing,not critical yet. <br /> 10 Drainfield is saturated and visibly discharging untreated effluent to the surface. Contact the City Inspector <br /> immediately.Repairs must be completed within 90 days. <br /> CONB4ENTS:_ S4}-�L fi�-�C� �va�� 01 <br /> b 1 0`1 0� <br /> Date of Inspection Matt Bolterman- Septic System Inspector <br /> Note: In the event that this inspection report is used to satisfy the requirements for a mortgage or other transfer of property,be advised that this report does <br /> not guarantee or certify that an cast"system will continue to function properly, but is merely an opinion of the adequacy of the system under current <br /> conditions bused on the available information. <br />