My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
06-19-1995 Planning Commission Minutes
Orono
>
Agendas, Minutes & Packets
>
Planning Commission
>
Minutes
>
1990-1999
>
1995
>
06-19-1995 Planning Commission Minutes
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/10/2019 1:50:39 PM
Creation date
7/10/2019 1:50:39 PM
Metadata
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
16
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
• <br />MINUTES OF THE ORONO PLANNING COMMISSION <br />MEETING HELD ON JUNE 19, 1995 <br />( 0) #3031 BRUCE R KELLY AND IRMA J, KELLY, 2340 FOX STREET - <br />PRELIMINARY SUBDIVISION - 8s30 -8!45 P.M. <br />The Certificate of Mailing and Affidavit of Publication were noted. <br />Mr. & Mrs. Kelly were present. <br />The property in question is located at the intersection of Fox Street and Willow Drive in a <br />RR B zone requiring 2 acre minimum lot size and 2 acres of contiguous dry buildable <br />land. The applicants propose a shared access at the existing curb cut, which has been <br />approved by the Engineer. Mabusth cautioned the owner that the driveway easement <br />would have an impact on division of Lot 1 in the fixture. The area of the vehicular <br />easement must be excluded from dry land area. It was noted that the top of the hill at the <br />east side of the new lot was an acceptable location. <br />Mabusth said there was a problem with the septic testing. The existing septic system <br />serving residence is located on Lot 2 and would not meet current septic standards. <br />Mabusth noted there appears to be no problem with the septic sites on the new lot, but <br />Staff is unable to locate the sites because the septic diagrams are not to scale. They need <br />to be redrawn to scale. Mabusth said new septic testing needs to be completed for <br />developed lot and a preliminary survey. An additional 5' is needed to have 200' of lot <br />• width to the rear of the 50' street setback. <br />The Applicant said both lots were over 200' wide. Kelly did not understand that the <br />easement area is deducted from the dry buildable. The reason for the subdivision is to <br />build a retirement -type home on the other lot. Kelly said the lot line was not necessarily <br />fixed, but he only wanted to make it easy and simple. Kelly understands that two new <br />septics are needed and cited a report saying there is adequate space on both lots for <br />mound systems. He does not understand the need for tabling the application. <br />Rowlette commented that the survey identifies the property. Kelly had thought the survey <br />was certified. Rowlette said she could not approve the application without 200' on Fox <br />Street for the new lot. Mabusth said structures need to be located in the field and setbacks <br />confirmed from a fixed lot line, and the locating of structures through topograpical <br />mapping does not satisfy requirements of a preliminary plat. <br />Schroeder said, although the Commission can not act on the application, direction can be <br />given. Schroder noted that the septic seems to meet the requirements. Rowlette said <br />caution was needed so as not to destroy a future subdivision. <br />Peterson moved, Nolan seconded, to table Application #2031 for City review of the septic <br />sites and for a survey pinpointing structures and wells. Ayes 7, Nays 0. <br />• <br />
The URL can be used to link to this page
Your browser does not support the video tag.