— 200412 GRT RM RIGHT <br /> TJ-Beam^" v5.45 Serial Number:7000005055 2 Pcs of 1.75" x 11.875" 2.0E Microllam® LVL <br /> BEAMUSA 1111 10/6/00 2:16:33 PM <br /> Page 1 of 2 Build Cade:124 <br /> THIS PRODUCT MEETS OR EXCEEDS THE SET DESIGN CONTROLS FOR THE APPLICATION AND LOADS LISTED <br /> nr In <br /> —16'2" <br /> Product Diagram is Conceptual. <br /> LOADS: <br /> Analysis for Header Member Supporting FLOOR-RES.Application. Tributary Load Width: 1' <br /> Loads(psf):40 Live at 100%duration, 15 Dead,0 Partition,and: <br /> TYPE CLASS LIVE DEAD LOCATION APPLICATION COMMENT <br /> Uniform lf) Floor(1.00) 40 15 0 to 16'2" Adds to <br /> Tapered(plf) Floor(1.00) 0 to 60 0 to 23 9'to 12' Adds to <br /> Uniform(plf) Floor(1.00) 349 128 12'to 16'2" Adds to <br /> Point(lbs.) Floor(1.00) 0 165 9' Adds to <br /> Point(lbs.) Floor(1.00) 0 80 12' Adds to <br /> SUPPORTS: INPUT BEARING REACTIONS(lbs.) <br /> WIDTH LENGTH JUSTIFICATION LIVE/DEAD/TOTAL DETAIL OTHER <br /> 1 Column 5.25" 4" Left Face 844/501 /1345 Detail A3 1.25"LSL Rim <br /> 2 Microllam®LVL 3.50" Hanger Right Face 1993/982/2976 Detail H1 <br /> -See Trus Joist SPECIFIER'S/BUILDER'S GUIDES for detail(s):A3, H1. <br /> HANGERS: Simpson Strong-Tie Connectors® <br /> REVERSE T.F. T.F. NAILING <br /> MODEL SLOPE SKEW FLANGES OFFSET SLOPE FACE TOP MEMBER <br /> Right Top WP1411.88 No N/A No 0 N/A 2-N10 2-N10 <br /> DESIGN CONTROLS: <br /> MAXIMUM DESIGN CONTROL CONTROL LOCATION <br /> Shear(lb) 2801 2209 7897 Passed(28%) Rt.end Span 1 under Floor loading <br /> Moment(ft-Ib) 6802 6802 19942 Passed(34%) MID Span 1 under Floor loading <br /> Live Defl.(in) 0.197 0.389 Passed(U947) MID Span 1 under Floor loading <br /> Total Defl.(in) 0.319 0.778 Passed(U585) MID Span 1 under Floor loading <br /> -Deflection Criteria:STANDARD(LL: U480,TL:U240). <br /> -Bracing(Lu):All compression edges(top and bottom)must be braced at 2'8"o/c unless detailed otherwise. Proper attachment and <br /> positioning of lateral bracing is required to achieve member stability. <br /> PROJECT INFORMATION OPERATOR INFORMATION: <br /> No Project Information available DFP PLANNING&DESIGN <br /> 4797 HWY. 10 NE ARDEN HILLS,MN <br /> 651-636-6889 <br /> 651-638-1412 <br /> ------------------------------ <br /> Copyright®2000 by Trus Joist,A Weyerhaeuser Business. TJ-ProT1 and TJ-Beam—are trademarks of Trus Joist. <br /> Simpson Strong-Tie Connectors®is a registered trademark of Simpson Strong-Tie Company,Inc. Microllame is a registered trademark of Trus Joist. <br />