My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2001-P04408 - new septic system
Orono
>
Property Files
>
Street Address
>
T
>
Turnham Road
>
385 Turnham Road - 31-118-23-31-0006
>
Septic
>
2001-P04408 - new septic system
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 4:30:34 PM
Creation date
7/3/2019 11:55:44 AM
Metadata
Fields
Template:
x Address Old
House Number
385
Street Name
Turnham
Street Type
Road
Address
385 Turnham Road
Document Type
Septic
PIN
3111823310006
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
19
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
S-P TESTING, INC. Steven B. Schirmers • MPCA Cert.No. 627 <br /> 951 Katydid Lane NE • St. Michael, MN 55376 • (763) 497-3566 <br /> FAX (763)-497-5011 <br /> State License#394 <br /> Revised September 17, 2001 <br /> July 21, 2001 CITY OF ORONO <br /> SEPTIC PERMIT REVIEW <br /> INSPECTOR <br /> DATE 9-Lk 6 I PERMIT NO. <br /> .I� APPROVED AS SUBMITTED <br /> Charles Phelps APPROVED WITH CORRECTIONS AS NOTED <br /> 385 Turnham Rd. NOT APPROVED-CORRECT&RESUBMIT <br /> These comments are for your information. All work shall be done <br /> Orono, Henn. Co., MN in fall compliance with all applicable optic and zoning code. <br /> Requirements including items not specifically noted in this review. <br /> UP TNU PLAN U?ON NTR AT ALL TihM <br /> This site has an existing on-site sewage treatment system which has been classified as <br /> failed by the City of Orono. The existing tanks will need to be abandoned, pumped and <br /> filled with soil. <br /> This on-site sewage treatment system is designed for a Type 1, four bedroom home, in <br /> accordance with the Minnesota Pollution Control Agency Chapter 7080 and local <br /> ordinances. <br /> The soils on this site are a clay loam. The seasonally saturated soils were located at <br /> 24" & 28" (mottled soil). Due to the seasonally saturated soils, a Pressurized Mound <br /> System will need to be installed to treat septic effluent. The bottom of the rock must be <br /> located at least 3' above the saturated soils. <br /> The soils at a depth of 12" have a percolation rate of 13.3 mpi. <br /> An addition is proposed for the house. If there is a full basement, a lift pump will be <br /> needed in the lower level to flow gravity to the existing flow line. Approximate elevation <br /> at the new addition is 94.9. <br /> A pumping chamber will need to be installed to lift the effluent to the treatment area. <br /> The power supply and switches must be located outside the manhole and pumping <br /> chamber in a weather proof enclosure. A warning device must be installed with a light <br /> and sound device, this is in case of a pump failure. <br /> 1 <br />
The URL can be used to link to this page
Your browser does not support the video tag.