Laserfiche WebLink
CITY of ORONO <br /> Municipal offices <br /> '� ,e ; 1�►G street Address: q5a-a49-460 0 Mailing Address:. <br /> 2750 Kelley Parkway P.U. Box 66 <br /> Orono, MN 55356 Crystal Clay, 55323-0066 <br /> To Current Owner: Address: �v/-e��q <br /> City Ordinance 199 requires that each existing on-site sewage treatment system in Orono be inspected every two years. <br /> The on-site sewage treatment system at the above address has been inspected and appears to fall into the categories checked below. <br /> ,SK <br /> STEM CONFORMITY (1-3): <br /> I "CODS SYSTEItit"An ISTS which meets all the location,design and construction standards of the current Orono Municipal Code. <br /> 2 "COMPLIANT SYSTEM" An ISTS which does not meet all the location,design and construction standards of the current Orono <br /> Municipal Code but does meet the three foot separation requirement or two foot requirement for systems installed 1996 or earlier,and <br /> which is not failing or an imminent threat to public health or safety. <br /> 3 "NON-COMPLIANT SYSTEM" A prohibited LSTs;an ISIS located within a designated 100-year flood plain,any ISTS which may <br /> Or may not meet all the location,design,or construction standards of the current Orono Municipal Code and which is failing for any <br /> reason;and any ISIS with less than three feet of unsatrarated soil or sand between the distribution device and the limiting soil characteristics. <br /> TANK CONDMON(5-7): <br /> Tank inspection indicates: <br /> 5 Pumpout not needed at this time. <br /> Qtic tanks must be pumped out this year (city code recommends tanks to be pumped out once every 3 years. <br /> Tank was last pumped, ), <br /> Make sure septic tanks are pumped through manhole and not through white insaeetion Pipes This allows for the proper <br /> cleaning. Keep water softner and iron filter discharge out of septic system to prolong life of drainfield Ask pumper to test <br /> alarm float to verify alarm is still working in-your house. The alarm warns owner that septage is about to backup into basement. <br /> 7 Inspection risers missing-tanks could not be' { " pipe)must be installed in each tank. If <br /> inspected. Inspection risers 4 dia. r <br /> tanks have not been pumped out within the last three years,they should be pumped out now. <br /> DRAINFIELD CONDMON(8-10): <br /> Drainfield is dry,no surfacing evident. <br /> Some evidence of surfacing,not critical yet. <br /> 10, Drainfield is saturated and visibly discharging untreated effluent to the surface. Contact the City Inspector <br /> immediately.Repairs must be completed within 90 days. <br /> Date of Inspection Matt Bolterman- Septic System Inspector <br /> Note: In the event that this inspection report is used to satisfy the requirements for a mortgage or other transfer of property,be advised dud this report does <br /> not guarantee or cemfy that an existing system will continue to function properly, but is merely an opinion of the adequacy of the system under current <br /> conditions based on the available information. <br />