My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1994-006143 - replace septic system
Orono
>
Property Files
>
Street Address
>
T
>
Turnham Road
>
380 Turnham Road - 31-118-23-42-0008
>
Septic
>
1994-006143 - replace septic system
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 4:32:11 PM
Creation date
7/3/2019 11:27:31 AM
Metadata
Fields
Template:
x Address Old
House Number
380
Street Name
Turnham
Street Type
Road
Address
380 Turnham Road
Document Type
Septic
PIN
3111823420008
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
24
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Koch's Soil Testing <br /> ` P.O. Box 81 <br /> t ` Loretto, MN 55357 <br /> Tel: (612)479-2637 <br /> rou,g Ferz 10/5/93 <br /> 380 Turnham Ad . <br /> Orono , Yinn. <br /> Job Site; Above Address <br /> rhe present drainfield was = leaching out on the surface at the <br /> end of the trenches. Therefore another site was tested to determine <br /> what type of drainfield could be installed and still meet the local <br /> codes. <br /> The average percolation rate in the area that was tested was 50. 7 min/in. <br /> And the depth to mottled soil was at 14-30 inches. <br /> * rotttled soil is consider the high seasonal water table that exist <br /> during the wet seasons and the minnmum depth to motlled soil in the <br /> City of Orono must be 54 inches or deepeer before a standard drainfield <br /> can be installed. ( City Codes ) . <br /> Therefore the only type of system that can be installed in th&s lot " <br /> Is a pressurized mound system. <br /> The size of--mound needed for a 4 bedroom home based. on ,600_.gal/day daily <br /> water useage and a perc. rate of 50. 7 min/in the sizing factors -would <br /> be 71 ft. long on the upslope, 103 ft. olong on the downslope and <br /> 58 ft. wide. The size - of the rock layer would need tb be 10 ft. wide <br /> by 55 ft. long ( 550 sq.ft. ) Or 29 tons of rock is required. , <br /> This mound rust be pressurized therefore a pump tank ( 1000 gallon) <br /> and a pump ( 4.0 g.p.m.-159 gal/cycle- 4 cyles/day) must be installed. <br /> An alarm system ( both a sound and a light alarm) must be installed <br /> In the house to indicate pump failure. <br /> * Dote ; This pump must be able to overcome at least 11 .7 ft. of head <br /> pressure. <br /> Two 1000 gallon are alreadis in place these tanks should ve inspected <br /> to make sure they meet the current codes, if . they do not meet the code <br /> then two new 1000 gallon tanks must be installed. <br /> Only clean wash sand should be used in this mound therefore this <br /> sand should be inspected by the local inspector to make sute it meets <br /> the code. , <br /> " <br /> Note; The land slolle were the system will be located on is 11 % <br /> therefore„ .local variance will have to be" granted as the .City Codes <br /> only a15ow° a maximum, slope of .6% for •.placement .of -mound ,system. <br /> However ,this is th0pnly avialable area to locate a system on. <br /> Due to t e jlo a" a d the presence of water" in the soil borings I <br /> suggest a' ai interceptor drain be installed on the top side <br /> of the mound to prevent water from flowing under and thru to mound. <br /> which might cause the mound to fail in the wet seasons. <br /> Site Evaluator <br /> Robert Koch <br /> 'Robert A.' -Koch <br /> MPCA Certified <br />
The URL can be used to link to this page
Your browser does not support the video tag.