Laserfiche WebLink
t 1 MAWMMN Right-J® Worksheet <br /> Job: <br /> ° •w°- -� Entire House Date: Dec.30th 2011 <br /> By: Jon B. <br /> 1 Room name Basement Zone Garage Zone <br /> 2 Exposed wall 238.0 ft 115.9 ft <br /> 3 Ceiling height 9.0 ft p 10.0 ft p <br /> 4 Room dimensions <br /> 5 Room area 2417.5 ft2 1080.0 ft2 <br /> Ty Construction U-value Or HTM Area (ft2) Load Area (ft2) Load <br /> number (Btuh/ft2-1F) (Btuh/ft2) or perimeter (ft) (Bt h) or perimeter (ft) (Btuh) <br /> Heat FC001 Gross N/P/S Heat Cool Gross N/P/S Heat Cool <br /> 6 12E-Osw 0.068 n 6.39 1.69 0 0 0 0 0 0 0 0 <br /> L---Ci 4A5-2ov 0.470 n 44.18 16.19 0 0 0 0 0 0 0 0 <br /> W 15A11-Oocw-6 0.103 n 6.56 0.58 189 189 1240 109 0 0 0 0 <br /> W 12E-Osw 0.068 ne 5.58 0.00 0 0 0 0 269 269 1498 0 <br /> 11 W 15A11-Oocw-6 0.103 ne 6.56 0.58 204 204 1336 117 0 0 0 0 <br /> 12E-Osw 0.068 a 6.39 1.69 0 0 0 0 0 0 0 0 <br /> 4A5-2ov 0.470 a 44.18 39.26 0 0 0 0 0 0 0 0 <br /> 11 GO 0.540 a 50.76 18.33 0 0 0 0 0 0 0 0 <br /> W 15A11.Oocw-6 0.103 a 6.56 0.58 576 576 3778 332 0 0 0 0 <br /> yJ 12E•Osw 0.068 se 5.72 0.29 0 0 0 0 424 184 1027 0 <br /> l-D 11N0 0.350 se 28.70 0.00 0 0 0 0 240 240 6888 0 <br /> W 15A11-Oocw-6 0.103 se 6.56 0.58 38 38 250 22 0 0 0 0 <br /> Val 12E-Osw 0.068 s 6.39 1.69 0 0 0 0 0 0 0 0 <br /> t-G 4A5-2ov 0.470 s 44.18 24.75 0 0 0 0 0 0 0 0 <br /> Val 15A11-Oocw-6 0.103 s 6.41 0.50 351 335 2142 168 0 0 0 0 <br /> L--G 4A5-2ov 0.470 s 44.18 24.75 17 0 729 408 0 0 0 0 <br /> WJ 12E-0sw 0.068 sw 5.87 0.60 0 0 0 0 42 42 237 0 <br /> t-G 4A5-2ov 0.470 sw 44.18 35.70 0 0 0 0 0 0 0 0 <br /> w 15A11-Oocw-6 0.103 sw 6.56 0.58 38 38 250 22 0 0 0 0 <br /> V 125-0sw 0.068 w 6.39 1.69 0 0 0 0 0 0 0 0 <br /> 4A5-2ov 0.470 w 44.18 45.14 0 0 0 0 0 0 0 0 <br /> 4A5-2ov 0.470 w 44.18 39.26 0 0 0 0 0 0 0 0 <br /> 4A5-2ovd 0.470 w 44.18 39.26 0 0 0 0 0 0 0 0 <br /> 15A11-Oocw-6 0.103 w 5.46 0.09 639 473 2582 42 0 0 0 0 <br /> 4A5-2ov 0.470 w 44.18 39.26 124 0 5486 4874 0 0 0 0 <br /> 4A5-2ovd 0.470 w 44.18 39.26 42 0 1856 1649 0 0 0 0 <br /> 12E-Osw 0.068 nw 5.70 0.25 0 0 0 0 424 404 2252 0 <br /> 4A5-2ov 0.470 nw 44.18 29.00 0 0 0 0 0 0 0 0 <br /> 11130 0.290 nw 23.78 0.00 0 0 0 0 20 20 486 0 <br /> W 15A11-Oocw-6 0.103 nw 6.56 0.58 108 108 712 63 0 0 0 0 <br /> R - 12C-Osw 0.091 - 0.00 1.73 0 0 0 0 0 0 0 0 <br /> L-D 11 PO 0.290 n 27.26 9.85 0 0 0 0 0 0 0 0 <br /> C 168-44ad 0.022 1.98 0.85 0 0 0 0 1080 1080 1948 0 <br /> C 16C-44a1 0.022 2.07 1.04 0 0 0 0 0 0 0 0 <br /> F 4580 n/a 0.00 0.00 2418 2418 0 0 1080 1080 0 0 <br /> 6 c)AED excursion 3370 0 <br /> Envelope loss/gain 20361 11176 14336 0 <br /> 12 a) Infiltration 1103 129 2520 0 <br /> b) Room ventilation 0 0 0 0 <br /> 13 Internal gains: Occupants @ 230 5 1150 0 0 <br /> Appliances/other 0 0 <br /> Subtotal(lines 6 to 13) 21464 12455 16856 0 <br /> Less external load 0 0 0 0 <br /> Less transfer 0 0 0 0 <br /> Redistribution 0 0 0 0 <br /> 14 Subtotal 21464 12455 16856 0 <br /> 15 Duct loads 0% 0% 0 0 0% 0% 0 0 <br /> Total room load 21464 12455 16856 0 <br /> Air required(cfm) 1 1 472 584 1 371 0 <br /> Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. <br /> wrilghtsoft` Right-Suite®Universal 8.0.18 RSU00282 2012-Jun-19 1 P3a7g:e 2 <br /> `��� ...y Documents\W rightsoft HVAC\Master Piece Homes-McClearen.rup Calc.MJ8 Front Door faces: <br />