My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2012-00589 - new structure
Orono
>
Property Files
>
Street Address
>
T
>
Turnham Road
>
125 Turnham Road - 31-118-23-43-0018
>
Permits/Inspections
>
2012-00589 - new structure
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 4:32:58 PM
Creation date
7/1/2019 2:09:39 PM
Metadata
Fields
Template:
x Address Old
House Number
125
Street Name
Turnham
Street Type
Road
Address
125 Turnham Road
Document Type
Permits/Inspections
PIN
3111823430018
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
56
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Project Summa Job <br /> t 1 MASSMANN 1 rY Date: Dec. .30th 2011 <br /> OEOENENMAL E MECNNNiCX Entire House By: Jon B. <br /> Project • • <br /> For: Rochel Residence, Masterpiece Homes <br /> 125 Turnham Road,Orono, MN <br /> Notes: <br /> Design Information <br /> Weather: Minneapolis-St. Paul, MN, US <br /> Winter Design Conditions Summer Design Conditions <br /> Outside db -22 OF Outside db 97 OF <br /> Inside db 68 of Inside db 75 of <br /> Design TD 90 OF Design TD 22 of <br /> Daily range M <br /> Relative humidity 45 % <br /> Moisture difference 57 gr/Ib <br /> Heating Summary Sensible Cooling Equipment Load Sizing <br /> Structure 74659 Btuh Structure 35070 Btuh <br /> Ducts 0 Btuh Ducts 0 Btuh <br /> Central vent(140 cfm) 6764 Btuh Central vent(140 cfm) 1649 Btuh <br /> Humidification 0 Btuh Blower 765 Btuh <br /> Piping 9285 Btuh <br /> Equipment load 90707 Btuh Use manufacturer's data n <br /> Rate/swing multiplier 1.02 <br /> Infiltration Equipment sensible load 38233 Btuh <br /> Method Simplified Latent Cooling Equipment Load Sizing <br /> Construction quality Tight <br /> Fireplaces 0 Structure 2278 Btuh <br /> Ducts 0 Btuh <br /> Heating Cooling Central vent(140 cfm) 2633 Btuh <br /> Area(ft2) 4835 4835 Equipment latent load 4911 Btuh <br /> Volume (ft3) 28098 28098 <br /> Air changes/hour 0.10 0.05 Equipment total load 43143 Btuh <br /> Equiv.AVF(cfm) 47 23 Req.total capacity at 0.70 SHR 4.6 ton <br /> Heating Equipment Summary Cooling Equipment Summary <br /> Make Enertech Manufacturing LLC. Make Enertech Manufacturing LLC. <br /> Trade GEOCOMFORT Trade GEOCOMFORT <br /> Model GT060 Cond GT060 <br /> AHRI ref no.3000398 Coil <br /> AHRI ref no.3000398 <br /> Efficiency 3.29 COP Efficiency 19.41 EER <br /> Heating input 46178 Btuh Sensible cooling 47913 Btuh <br /> Heating output 46178 Btuh Latent cooling 20534 Btuh <br /> Temperature rise 26 of Total cooling 68447 Btuh <br /> Actual air flow 1643 cfm Actual air flow 1643 cfm <br /> Air flow factor 0.022 cfm/Btuh Air flow factor 0.047 cfm/Btuh <br /> Static pressure 0.50 in H2O Static pressure 0.50 in H2O <br /> Space thermostat Load sensible heat ratio 0.88 <br /> Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. <br /> .� �y wri htSoft° 2012-Jun-1915:37:30 <br /> 1 9 Right-Suite®Universal 8.0.18 RS000282 Page 1 <br /> ACC;A ...y Documents\Wrightsoft HVAC\Master Piece Homes-McClearen.rup Calc=MJ8 Front Door faces: <br />
The URL can be used to link to this page
Your browser does not support the video tag.