My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1999-011260 - htg/ac/vent
Orono
>
Property Files
>
Street Address
>
T
>
Truffula Trail
>
040 Truffula Trail- 33-118-23-44-0035
>
Permits/Inspections
>
1999-011260 - htg/ac/vent
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 4:52:53 PM
Creation date
7/1/2019 9:05:26 AM
Metadata
Fields
Template:
x Address Old
House Number
40
Street Name
Truffula
Street Type
Trail
Address
40 Truffula Trail
Document Type
Permits/Inspections
PIN
3311823440035
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
4
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
RHVAC-Residential 8 Light Commetclai HVAC Lbada Program Elita aat'twaro be0loptrmant,ihe. <br /> Ditter,Inc. 2-9-s9 A T 1360loprmnt <br /> Hamel,MN 55340-9691 page 2 <br /> Project Summary <br /> Project: A&T Development Company: Ditter Inc. Cooling & Heating <br /> Client: A&T Development Representative: Doug Bjork <br /> Address: 40 Truffla Trail Address: 820 Tower Drive <br /> City: Orono, MN. City: Hamel, MN. 55343 <br /> Phone: Phone: 478-9558 <br /> Fax: Fax: 478-2426 <br /> Comment: <br /> Design Data <br /> Project Name: A&T Development <br /> Reference City: Minneapolis, Minnesota <br /> Daily Temperature Range: Medium <br /> Latitude: 44 Degrees <br /> Elevation: 834 Feet <br /> Elevation Sensible Adj. Factor: 1.000 <br /> Elevation Total Adj. Factor: 1.000 <br /> Outdoor Outdoor Indoor Indoor Grains <br /> Dry Bulb Wet Bulb Rel.Hum. Dry Bulb Difference <br /> Winter: -20 N/A N/A 72 N/A <br /> Summer: 95 75 50% 75 36 <br /> Check Figures <br /> Total Building Supply CFM: 1154 CFM per square foot: 0.769 <br /> Square feet of room area: 1,500 Square feet per ton: 562.591 <br /> Building Loads <br /> Total heating required with outside air: 66,103 Btuh 66.103 MBH <br /> Total sensible gain: 24,636 Btuh 82 % <br /> Total latent gain: 5,372 Btuh 18 % <br /> Total cooling required with outside air: 30,008 Btuh 2.501 Tons(based on sensible + latent) <br /> 2.666 Tons (based on 77% sensible capacity) <br /> Notes <br /> Calculations are based on 7th edition of ACCA Manual J. <br /> All computed results are estimates as building use and weather may vary. <br /> Be sure to select a unit that meets both sensible and latent loads. <br /> Tuesday,February 09,1999 <br />
The URL can be used to link to this page
Your browser does not support the video tag.