Laserfiche WebLink
CONSTRUCTION R VALUE <br /> ' WALL FRAMING SECTION: <br /> � � „� �•�� ( 1 INTERIOR AIR FILM 0. 68 <br /> t ( 2 1 2 GYPSUM BOARD0.45 <br /> ( 3 3 1 2 INCHES SOFT WOOD 6 . 87 <br /> 1 (4 2 FIBERBOARD SHEATHING 2 . 06 <br /> s ( 5 SIDING 0. 81 <br /> s ( 6 EXTERIOR AIR FILM 0. 1 <br /> TOTAL R = 11 . 04 <br /> U = 1/R = . 09 <br /> STUCCO SIDING BRICK WALL SECTION ( INSULATED) : <br /> ( 1 INTERIOR AIR FILM 0 . 68 . <br /> ( 2 1/2" GYPSUM BOARD 0 .45 <br /> (3 FIBERGLASS INSULATION 19 . 00 <br /> (4 25/32" FIBERBOARD SHEATHING 2 . 0 <br /> (5 SIDING 0 . 91 <br /> ( 6 EXTERIOR AIR FILM 0 . 1 <br /> ! TOTAL R = 23 . 17 <br /> � s <br /> U = 1/R = -- 00 <br /> RIM JOIST SECTION: <br /> (1 INTERIOR AIR FILM 0 . 68 <br /> ( 2 FIBERGLASS INSULATION 19 . 00 <br /> (3 INCHES SOFT WOOD 1 . 89 <br /> (4 257T2 FIBERBOARD SHEATHING 2. 0 <br /> ( 5 SIDING 0 . 9-1 <br /> ( 6 EXTERIOR AIR FILM 0. 17 <br /> TOTAL R = 24. 61 <br /> U = 1/R = . 0�+ <br /> 777' FOUNDATION SECTION: <br /> 117 —_ (1 INTERIOR AIR FILM 0. 68 <br /> i (2 TT1coNCRETE BLOCK 1 . 2 <br /> (3 RIGID INSULATION TO FROST 10. 00 <br /> --- �; (4 EXTERIOR AIR FILM 0. 1 <br /> (5 <br /> TOTAL R = <br /> s 4 U = 1/R = �$ <br /> " !ii _ <br /> :.1 s <br /> 77 i- <br />