My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2015-00906 - septic
Orono
>
Property Files
>
Street Address
>
T
>
Townline Road
>
1180 Townline Road - 30-118-23-32-0001
>
Septic
>
2015-00906 - septic
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 4:27:20 PM
Creation date
6/27/2019 3:11:36 PM
Metadata
Fields
Template:
x Address Old
House Number
1180
Street Name
Town Line
Street Type
Road
Address
1180 Town Line Road
Document Type
Septic
PIN
3011823320001
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
40
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
on OSTP Design Summary Worksheet UNIVERSITY <br /> Minnesota Agency OF MINNESOTA <br /> A9 Y <br /> Property Owner/Client:IMichael Theis Estate Project ID: v 03.19.15 <br /> Site Address: 1180 Town Line Road,Orono Hennepin County Date: 7/6/15 <br /> 1. DESIGN FLOW AND TANKS <br /> A. Design Flow: 600 Gallons Per Day(GPD) Note: The estimated design flow is considered a peak flow rate <br /> including a safety factor.For long term performance,the average <br /> B. Septic Tanks: daily flow is recommended to be<60%of this value. <br /> Minimum Code Required Septic Tank Capacity: 2-250-7 Gallons,in Tanks or Compartments <br /> Recommended Septic Tank Capacity: 2250 Gallons,in Tanks or Compartments <br /> Effluent Screen: no Alarm: no <br /> C. Holding Tanks Only: <br /> Minimum Code Required Capacity: Gallons.in Tanks <br /> Designer Recommended Capacity: Gallons,in �Tanks <br /> Type of High Level Alarm: <br /> D. Pump Tank 1 Capacity(Code Minimum): Gallons pump Tank 2 Capacity(Code Minimum): Gallons <br /> Pump Tank f Capacity(Designer Rec): Gallons Pump Tank 2 Capacity(Designer Rec): Gallons <br /> Pump 1 1 38.0 GPM Total Head 27,2 ft Pump 2GPM Total Head �ft <br /> Supply Pipe Dia. 2.00 in Dose Volume:=gal Supply Pipe Dia.E=in Dose Volume:==gat <br /> 2. SYSTEM TYPE <br /> * Trench Q Bed Q Mound O At-Grade 0 Gravity Distnbution 09 Pressure Distribution-Level O Pressure D`stritiution-Lh 1 <br /> ©Drip Q Holding Tank Other "Selection Required Benchmark Elevation: 100.00 ft <br /> Benchmark Location: top of threshold <br /> System Type Type of Distribution Media: <br /> 0 Type I ❑Type I l ❑Type 11l ❑Type IV E'Type V 2' Drainfield Rod` Registered Treatment Media: <br /> 3. SITE EVALUATION: <br /> A. Depth to Limiting Layer: 20 in =ft B. Measured Land Slope%: 7.0 % <br /> C. Elevation of Limiting Layer:I 105.9 D. Soil Texture: Clay Loam <br /> E. Loc.of Restricive Elevation: F. Soil Hyd.Loading Rate: 0.45 GPD/ft' <br /> G. Minimum Required Separation: 36 in 3.0 ft H. Perc Rate: 10.0 MPI <br /> I. Code Maximum Depth of System: Mound in Comments: <br /> 4. DESIGN SUMMARY <br /> Trench Design Summary <br /> Dispersal Areaft` Sidewall Depthin Trench Widthft <br /> Total Lineal FeetNumber of Trenches Code Maximum Trench Depthin <br /> Contour Loading RateE==ft Designer's Max Trench DepthF—=in <br /> Bed Design Summary <br /> Absorption Areaftz Depth of sidewallin Code Maximum Bed Depthin <br /> Bed Width=ft Bed LengthE=ft Designer's Max Bed DepthE=in <br />