My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1994-006102 - septic system
Orono
>
Property Files
>
Street Address
>
T
>
Townline Road
>
1040 Townline Road - 30-118-23-32-0004
>
Septic
>
1994-006102 - septic system
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 4:27:22 PM
Creation date
6/27/2019 1:15:31 PM
Metadata
Fields
Template:
x Address Old
House Number
1040
Street Name
Town Line
Street Type
Road
Address
1040 Town Line Road
Document Type
Septic
PIN
3011823320004
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
24
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
S-P .TESTING, INC. Steven B. Schirmers — MPCA Cert. No. 627 <br /> 951 Katydid Lane NE • St. Michael, MN 55376 • (612) 497-3566 <br /> October 4, 1993 <br /> Charles Kickhafer <br /> 1040 Townline Rd. <br /> Orono, Henn. Co. , MN <br /> This On-Site Sewage Treatment System is Designed for a Type 1, three <br /> bedroom home in accordance with the Minnesota Pollution Control <br /> Agency Chapter 7080 and local ordinances . <br /> The soils on this site are SCS soils mapped - KkB - Kilkenny <br /> loam. A seasonally high water table was located at 22" & 26" <br /> (mottled soil ) . Due to the seasonally high water table, a <br /> Pressurized Mound System will need to be installed. The bottom <br /> of the rock bed must be located at least 3 ' above the seasonally <br /> high water table. <br /> This site has an existing failing system due to the high water <br /> table. The existing tanks may be used upon approval by the <br /> City Inspector. They must be water tight,also tanks may be under sized <br /> 750 gal . and will need .to be abandoned. <br /> The soils at a depth of 12" have a percolation rate averaging <br /> 4. 1 min/inch. <br /> A pumping chamber will need to be installed to lift the effluent <br /> to the treatment area. <br /> The manifold and supply line pipe must have back drainage to the pumping <br /> chamber. The distribution pipes shall have their ends capped. Be sure <br /> the rock and sand fill material are clean. The sod layer below the <br /> entire mounded area must be turned over, just break up the sod, be sure <br /> not to over work. <br /> The power supply and switches must be located outside the manhole and <br /> pumping chamber in a weather proof enclosure . A warning device must <br /> be installed with a light and sound device, this is in case of a pump <br /> failure . Mercury floats are a good method. <br /> All neighboring wells are located greater than 75 ' away from the <br /> proposed treatment area. <br /> CONT'D <br />