2018-00390 - pool
Orono
>
Property Files
>
Street Address
>
T
>
Tonkawa Road
>
1020 Tonkawa Road - 08-117-23-13-0014
>
Permits/Inspections
>
2018-00390 - pool
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 5:41:44 PM
Creation date
6/12/2019 1:59:42 PM
Metadata
Fields
Template:
x Address Old
House Number
1020
Street Name
Tonkawa
Street Type
Road
Address
1020 Tonkawa Rd
Document Type
Permits/Inspections
PIN
0811723130014
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
22
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
PERIMETER DEFLECTION TEST <br /> The perimeter deflection test was conducted on both Cover-Pool safety covers In <br /> accordance with section 9.2 of ASTM ES '13. With a 50 Ib. weight placed 4' from the <br /> edge of the pool on top of the safety cover, the test object was unable to pass through <br /> any opening at the perimeter of the pool. Both Cover-Pool safety covers met the <br /> performance requirements for the perimeter deflection test as outlined in ASTM ES 13 <br /> section 7.2. <br /> SURFACE DRAINAGE TEST <br /> On June 12, 1990, the surface drainage test was conducted on a Cover-Pool safety <br /> cover which was installed on a local private pool. The tracking system was an under <br /> track system. The pool dimensions were 14.17'x42.5'. The surface drainage test was <br /> conducted in accordance with ASTM ES 13 section 9.3. Water was applied evenly at <br /> a rate of 11.7 gpm per 1000 sq. ft. A small sump pump, with discharge capacity of 20 <br /> gpm, was placed at one end of the safety cover with the discharge hose snaking the <br /> length of the pool, on top of the safety cover, and discharging at the opposite end from <br /> the pump. The water was applied for 30 minutes with the pump on and in place. The <br /> water was then shut off and the pump was allowed to run for an additional 30 minutes. _ <br /> The test mannequin (Timmy) was then placed upon the safety cover. At the end of 3 <br /> minutes after placing Timmy upon the safety cover, an unsafe amount of water as <br /> described in ASTM ES 13 section 9.3.1 did not exist. The Cover-Pool safety cover met <br /> the safety requirements as outlined in ASTM ES 13 section 7.3. <br /> All safety covers and equipment tested were standard as provided by Cover-Pools Inc. Safety covers <br /> were installed according to Cover-Pdols, Inc. standard installation criteria. <br /> Inspector: Jerry Hall <br /> RESULTS ARE APPLICABLE ONLY To SPECIFIC SAMPLES TESTED. <br /> REPORTS ANY Nor BE REPRODUCED.EXCEPT IN FULL.YMTIIOUT <br /> WRITTEN PERMISSION BY PSI.INC. <br /> Respectfully submitted, <br /> Professional Service Indus(ries, Inc. <br /> Jerry G.Hall <br /> Department Manager <br /> i <br />