Property address: 1180 Homestead Trail Inspector initials/Date: RLP i 06/05/2019 <br /> (mm/dd/yyyy) <br /> 4. Soil Separation — Compliance component#4 of 5 <br /> Date of installation: 06/05/2019 ❑ Unknown Verification method(s): <br /> (mm/dd/yyyy) <br /> Shoreland/Wellhead protection/Food beverage Soil observation does not expire. Previous soil <br /> lodging? ❑Yes 1:1No observations by two independent parties are sufficient, <br /> unless site conditions have been altered or local <br /> Compliance criteria: requirements differ. <br /> For systems built prior to April 1, 1996, and El Yes ® No ❑ Conducted soil observation(s)(Attach boring logs) <br /> not located in Shoreland or Wellhead <br /> ❑Two previous verifications(Attach boring logs) <br /> Protection Area or not serving a food, <br /> beverage or lodging establishment: ❑ Not applicable(Holding tank(s),no drain field) <br /> Drainfield has at least a two-foot vertical ❑ Unable to verify(See Comments/Explanation) <br /> separation distance from periodically ❑ Other(See Comments/Explanation) <br /> saturated soil or bedrock. <br /> Non-performance systems built April 1, ®Yes ❑ No Comments/Explanation: New installation of septic system <br /> 1996, or later or for non-performance <br /> systems located in Shoreland or Wellhead <br /> Protection Areas or serving a food, <br /> beverage, or lodging establishment: <br /> Drainfield has a three-foot vertical <br /> separation distance from periodically <br /> saturated soil or bedrock.* <br /> "Experimental", "Other", or "Performance" ❑Yes ® No Indicate depths or elevations <br /> systems built under pre-2008 Rules; Type IV 992.7 <br /> or V systems built under 2008 Rules(7080. A. Bottom of distribution media <br /> 2350 or 7080.2400 (Advanced Inspector <br /> License required) B. Periodically saturated soil/bedrock 989.7 <br /> Drainfield meets the designed verticalC. System separation 3� <br /> separation distance from periodically <br /> saturated soil or bedrock. D. Required compliance separation* 3' <br /> Any "no"answer above indicates the system is *May be reduced up to 15 percent if allowed by Local <br /> failing to protect groundwater. Ordinance. <br /> 5. Operating Permit and Nitrogen BMP*—Compliance component#5 of 5 ❑ Not applicable <br /> Is the system operated under an Operating Permit? ❑Yes ❑ No If"yes",A below is required <br /> Is the system required to employ a Nitrogen BMP? El Yes ❑ No If"yes", B below is required <br /> BMP=Best Management Practice(s)specified in the system design <br /> If the answer to both questions is "no", this section does not need to be completed. <br /> Compliance criteria <br /> a. Operating Permit number: <br /> ❑Yes ❑ No <br /> Have the Operating Permit requirements been met? <br /> b. Is the required nitrogen BMP in place and properly functioning? ❑Yes ❑ No <br /> Any "no"answer indicates Noncompliance. <br /> Upgrade Requirements(Minn. Stat.§115.55)An imminent threat to public health and safety(ITPHS)must be upgraded, replaced, or its use <br /> discontinued within ten months of receipt of this notice.If the system is failing to protect ground water, the system must be upgraded,replaced, <br /> or its use discontinued within three years of receipt of this notice.If an existing system is not failing as defined in law, and has at least two feet <br /> of design soil separation,then the system need not be upgraded, repaired,replaced, or its use discontinued. This provision does not apply to <br /> systems in shoreland areas, Wellhead Protection Areas,or those used in connection with food, beverage, and lodging establishments as <br /> defined in law. <br /> Page 3 of 3 <br />