Laserfiche WebLink
vcNiwaUVII mcaau11VIIIWIn LJV%,UiIFUI1wuvIi <br /> 13 Address: 847 Tonkawa Road Date: <br /> Completed B : Kevin Kamerud Co. Name: Stonewood <br /> de: <br /> C Orono <br /> p y Stonewood Design Build, LLC � <br /> Path 2, Aggregate Albemative Co Alam,: Required <br /> T--T- - Installed: Yes No - - <br /> Ventilation: Measured Per6om>lance <br /> People Ventilation Supplemental Ventilation Total Ventilation <br /> Minimums---> 75 356 431 <br /> rMeasured Measured <br /> People Designed Intake Exhaust Supplemental Designed Intake Exhaust <br /> HRV or ERV 1 152 cfm. HRV or ERV 1 87 cfm. <br /> — -- <br /> Kitchen Exhaust 0 cfm. Kitchen Exhaust 350 cfm. <br /> Master Bathroom 0 cfm. _ Master Bathroom - 80 cfm. <br /> Bsmt Bathroom 0 cfm. Bsmt Bathroom 80 cfm. <br /> 1st FI Bathroom 0 cfm. 1st Fl Bathroom 80 cfm. <br /> People: 152 cfm. Supplemental: --t677 cfm. <br /> Note: Air flow for balanced ventilations stems must be balanced within ten percent. <br /> Compliance Statement:Installed ventilation system is in compliance with the MN Energy Code and sized to provide the design air flow. <br /> Applicant(print name) Signa Date Phone number <br />