My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1993-005670 - whirlpool tub
Orono
>
Property Files
>
Street Address
>
T
>
Tonkawa Road
>
0801 Tonkawa Road - 08-117-23-21-0001
>
Permits/Inspections
>
1993-005670 - whirlpool tub
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 3:16:49 PM
Creation date
6/10/2019 1:23:31 PM
Metadata
Fields
Template:
x Address Old
Address
0801 Tonkawa Rd
Document Type
Permits/Inspections
PIN
0811723210001
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
16
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
VERSA THE UNIVERSAL POOUSPA HEATERS <br /> IN VERSA <br /> _ Seven sizes of VERSA heaters are available in <br /> stackless models and optional outdoor stack* for <br /> outdoor installation and with draft hoods for <br /> indoor installation. See the sizing tables below for <br /> model selection. All sizes are available in millivolt <br /> models with single thermostats. Electronic ignition <br /> models are furnished with single thermostat on <br /> Models 055B through 155B, and with dual <br /> thermostats on Models 185B through 405B. Dual <br /> thermostat kits are available for millivolt Models <br /> 1858 through 4058. 'Not available on 0558 <br /> HOW TO SELECT THE RIGHT SIZE VERSA HEATER— <br /> FOR YOUR SWIMMING POOL RECOMMENDED RAYPAK VERSA MODEL <br /> I.Determine your pool size in square feet. Your <br /> 2.Decide how you plan to use your pool: Pool Size Temperature Energy-Saving <br /> If pool use will be on a daily basis,you may wish to keep it heated continu- ISq.Ft l Maintenance Rapid Heating <br /> ously. Refer to the column headed TEMPERATURE MAINTENANCE in the table— <br /> it selects the minimum heater size recommended to keep your pool comfortable � � 1556 658 <br /> under normal conditions. If you wish to maximize energy savings,avoid heating s 0.3356' <br /> your pool when it's not being used.Refer to the column headed RAPID HEAT 11i'"''1 `'C 1558' +"" Cd356°• <br /> ING—it selects a larger heater capable of raising the water temperature quickly. i 4�`.•C*1858. fi?` ' y.'! '�-1058 <br /> 3.When in doubt,or if your pool is subjected,to excessive winds,always select ODi <br /> a larger size heater—the added initial cost will be more than offset by the fuel h <br /> savings and convenience of rapid heating. <br /> Table is based on 31h MPH average wind velocity and elevation of less than 20001t.above sea level. 4 <br /> Hlgner winds or elevations decrease temperature rise and a largemized heater will be required. <br /> Heater Spa/rub Size in Gallons <br /> FOR YOUR SHA OR HOT TUB Model 300 400 500 600 700 800 <br /> 1.Determine spa capacity in gallons surface area x average depth x 71/2. pesireti Temp:Rise Ir►vF."per hour l: <br /> 2.Determine the desired temperature rise—the difference between the spa -055!3 16 •++ 12 lI0 " : ;. , J <br /> 8 7 <br /> water standby temperature and the spa temperature you prefer. <br /> 3.The table lists the temperature rise per hour which can be attained by each -105A "34; <br /> 5 20 1 17 t l 4 t3 <br /> heater model for several spa sizes.Select the heater model which will provide -1556 ..1` 48 ; ,':':36 t'29 24.', 21 `I <br /> the desired temperature rise in the desired elapsed time. =1858 1 54„ 30 ' 25 <br /> Example:500 gal.spa, 30°F rise desired.Model 1558 will recover 29°F per hour. 2658" 84` t 43 ►.' SI' :'!i42'l=f'F3/ i' `"' 3 <br /> Model 3358 will recover 63°F per hour Note:Heat losses and/or heat absorbed 3356 ''104 i:>i7.8: + ,63 52"� '^45 <br /> by spa walls or other objects will add to the heat-up time. <br /> Spa sizing is based on an insulated and covered spa.Always cover your spa or hot tub when not in <br /> use to minimize heat loss and evaporation,and to decrease the time needed to heat the water. <br /> SPECIFICATIONS AND DIMENSIONS F Moan 105A <br /> ModN 0558 � ! <br /> Single or Dual Shipping y • <br /> BTU IA) (8) Temp.Controls Water Weights Ilbs) —I mm <br /> Input Cabinet Flue Milli- Electronic Connects. Heater Slackless Outdoor Draft 24V - roam li o I� <br /> Model )000) Width Dia. volts Ignition I'h" 2" Base Top Stack Hood 2W iip I it I uy <br /> 558; 6p"18k° ; : + $ ,; ✓ No' <br /> 70t : 5 No F 1 1 1 1 <br /> 0SA'�'"I S'''24A�'+;, � ,3 .,;r ✓ ,:r No " I US 8,. 7 I-au ! I-- � --.) htyr A <br /> 155 151' 14 ' $1 r%x`✓ I ✓ :'t 95 I t` ModN I SS8 Models 1858 tfuu 4058 <br /> i1�sa I�ai RI ',,til �, {'180 24' ` '9 1 _ <br /> rr -1 VIM <br /> 2658, 264 :;a e' $•� d s ✓ ✓ ' 185. . 25` 11 I T' � �. <br /> 3333 �73Jt"';'•9" ' S. . p Il, +>+ ✓ ✓ 215 26 14 19• sv, eov. <br /> �''•" exam <br /> WM <br /> Z, Lm �m � <br /> Above input ratings are per A.G.A.specifications.Reduce input 4%for each 100011.above sea level 1 <br /> when installed above 2000 It.elevation.Manufactured under Patent No.3.623,458. Y 1 I feo�lt <br /> 'Optional Dual Control Kit available. I--A <br /> AW <br /> Outdoor Stack <br /> � "APO <br /> . 105 •46%' <br /> 155 50' V <br /> 185 53k' <br /> 235 5 %" <br /> RAYPAK, INC. 31111 Agoura Road, Westlake Village, CA 91361 (818)889-1500 335 5 <br /> 9'b" H <br /> 405 6zw' ` <br /> Utho in U.SA 01989 RaypaK Inc. Catalog No.6000.100 Eff: 1-1.92 <br /> Rayp<ik reserves the fight to change these 1pLx 111(allom without nUhc e <br />
The URL can be used to link to this page
Your browser does not support the video tag.