GENERAL NOTES:
<br />1. SHARRATT DESIGN e COMPANY MAKES NO WARRANTY AS TO THE EXACT CONDITIONS TO BE ENCOUNTERED
<br />ON SITE. THESE DRAWINGS ARE PROVIDED TO DELINEATE THE DESIGN INTENT ONLY. IT IS THE RESPONSIBILITY
<br />OF THE CONTRACTOR AND SUB -CONTRACTORS TO PERFORM FIELD INVESTIGATION BEFORE UNDERTAKING ANY
<br />DEMOLITION OR RECONSTRUCTION ACTIVITY. G.G. AND ALL SUB -CONTRACTORS SHALL COMPLETELY
<br />FAMILIARIZE THEMSELVES WITH EXISTING CONDITIONS BY VISITING THE SITE PRIOR TO SUBMITTING THEIR
<br />PROPOSALS.
<br />2. THE DEMOLITION NOTES AS SHOWN IN THESE DRAWINGS GENERALLY OUTLINE VARIOUS ITEMS OF
<br />DEMOLITION WORK. THEY ARE NOT TO BE CONSTRUED AS INCLUSIVE OF ALL GUTTING, DEMOLITION OF FINISHES
<br />AND REQUIRED PATCHING. ALL TRADES ARE EXPECTED TO READ ALL DEMOLITION NOTES.
<br />3. SHARRATT DESIGN $_: COMPANY RECOMMENDS STRUCTURAL ENGINEERING FOR ALL PROJECTS. IF CLIENT
<br />ELECTS NOT TO HAVE ENGINEERING PROVIDED, GENERAL CONTRACTOR ASSUMES RESPONSIBILITY FOR
<br />STRUCTURAL ENGINEERING AND RELATED RISK, AND FOR COORDINATION OF ENGINEERING WITH THERMAL.,
<br />MOISTURE, AND BULK WATER ENVELOPES.
<br />4. WARRANTIES SHALL BE IN ACCORDANCE WITH STATE MINIMUM STANDARDS OR GREATER. REGISTERED
<br />BUILDER PROGRAMS AND/OR PRODUCT WARRANTIES. LIABILITY AND WORKER'S COMPENSATION CERTIFICATE
<br />OF INSURANCE WILL BE REQUIRED FROM ALL SUBCONTRACTORS.
<br />5. GENERAL CONTRACTOR AND ALL SUBCONTRACTORS TO VERIFY AND COORDINATE ALL CONDITIONS AND
<br />DIMENSIONS PRIOR TO WORK THROUGH THE ENTIRE BUILDING PROCESS. G.G. TO CONTACT GOPHER ONE TO
<br />VERIFY LOCATIONS OF ALL UNDERGROUND ELEGTRIGAL, UTILITIES, SEWER, GABLE, GAS, ETC. PRIOR TO
<br />GOI" II" IENGING WORK. IMMEDIATELY REPORT AND/OR REVIEW ALL QUESTIONS, DISCREPANCIES AND
<br />CONDITIONS WITH THE OWNER/ARCHITECT PRIOR TO PROCEEDING WITH WORK.
<br />0. ALL CONSTRUCTION AND/OR MATERIALS AS INDICATED SHALL BE AT OR ABOVE INDUSTRY STANDARDS FOR
<br />SIMILAR GUSTO" RESIDENTIAL CONSTRUCTION.
<br />7. ALL CONSTRUCTION WORK SHALL GONFOR-1 TO ALL APPLICABLE CODES.
<br />8. ALL SURVEY DATA, SOIL DATA, MECHANICAL, ELECTRICAL, AND STRUCTURAL ENGINEERING OF SYSTEMS,
<br />SIZES AND LAYOUTS (INCLUDING TRUSS, FRAMING, AND GIRDER DESIGN) SHALL BE BY THE RESPECTIVE
<br />SUBCONTRACTOR AND/OR SUPPLIER OF THOSE SYSTEMS OR BY OTHER NECESSARY CONSULTANTS AND
<br />SHALL BE COORDINATED BY THE GENERAL CONTRACTOR. INFORMATION SHOWN IN REGARD TO THESE
<br />CONCERNS IS ONLY DIAGRAMMATIC AND IS INTENDED TO PROVIDE AN INDICATION OF THE DESIGN INTENT
<br />ONLY. USE OF CONSULTANT DATA BY SDG DOES NOT INFER OR ENDORSE THE ACCURACY OF THE DATA.
<br />EACH CONSULTANT AND CONTRACTOR SHALL BE RESPONSIBLE FOR GORREGTNESS AND AGGURAGY OF DATA
<br />SUPPLIED BY THE RESPECTIVE CONSULTANT AND/OR CONTRACTOR.
<br />9. GENERAL CONTRACTOR SHALL COORDINATE AND SITE THE BUILDING ON THE OWNER'S LEGAL SURVEY.
<br />GENERAL CONTRACTOR TO NOTIFY OWNER AND/OR ARCHITECT OF ANY DISCOVERED DISCREPANCIES PRIOR
<br />TO ANY SITE WORK.
<br />10. GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR SHORING AND BRACING AND FOR ALL TEMPORARY
<br />FACILITIES �. SERVICES, INCLUDING BUT NOT LIMITED TO POWER, WATER, TELEPHONE, FAX, SANITATION
<br />FACILITIES AND FIRE FIGHTING EQUIPMENT.
<br />11. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL REQUIRED EROSION CONTROL MEASURES AND ANY
<br />SPEGIFIG ENVIRONMENTAL IMPACT ISSUES ARISING FROM CONSTRUCTION ON THE SITE.
<br />12. THE GONTRAGTOR SHALL MAINTAIN THE SITE IN FIRST -GLASS CONDITION DURING THE PROJECT. ALL WASTE
<br />AND DEBRIS SHALL PROMPTLY BE REMOVED. CONSIDERATION SHALL BE GIVEN TO MATERIAL STORAGE ON
<br />THE SITE AND ITS IMPACT ON ADJOINING NEIGHBORS.
<br />13. THE CONTRACTOR SHALL PROVIDE FINAL GLEANING OF ALL INTERIOR AND EXTERIOR SURFACES. ALL
<br />TRANSPARENT MATERIALS ARE TO BE LEFT IN A POLISHED CONDITION. REMOVE ALL LABELS THAT ARE NOT
<br />INTENDED TO REMAIN AS PERMANENT INSTRUCTION INFORMATION.
<br />14. GENERAL CONTRACTOR SHALL PROVIDE INSTRUCTIONS TO THE OWNER PERTAINING TO OPERATION AND
<br />MAINTENANCE OF MEGHANIGAL AND ELECTRICAL EQUIPMENT. COMPILE AND FORWARD TO THE OWNER ALL
<br />MAINTENANCE AND OPERATIONS DATA AND WARRANTIES IN THE FORM OF A WELL -ORGANIZED OWNERS
<br />NOTEBOOK.
<br />15. ROOF TRUSS ENGINEERING AND DESIGN TO BE PROVIDED BY TRUSS SUPPLIER. TRUSS SUPPLIER TO FIELD -
<br />VERIFY ALL FRAMED DIMENSIONS AND CONDITIONS PRIOR TO TRUSS FABRICATION. TRUSS SUPPLIER TO
<br />COORDINATE FINAL TRUSS SOLUTION WITH PROJECT STRUCTURAL ENGINEER AND/OR GENERAL CONTRACTOR.
<br />TRUSS SUPPLIER TO COORDINATE TRUSS DESIGN WITH ENERGY HEEL REQUIREMENTS.
<br />10. ALL WINDOW DESIGNATIONS ARE FOR MARVIN WINDOWS. CONTRACTOR MAY PROVIDE BID ALTERNATE
<br />FOR OTHER WINDOW MANUFACTURERS - SEE SPEGIFIGATIONS FOR ALTERNATES. SUPPLIER TO SUBMIT
<br />WINDOW SCHEDULE TO GENERAL CONTRACTOR AND OWNER FOR REVIEW AND APPROVAL PRIOR TO PLACING
<br />WINDOW ORDER. GENERAL CONTRACTOR TO CONFIRM TEMPERED GLASS LOGATIONS, EGRESS AND VENT
<br />WINDOW REQUIREMENTS, LITE PATTERNS, WINDOWSIZES, WINDOW OPERATION, JAMB SIZES, EXTENSION
<br />JAMBS, ETC. W/OWNER. WINDOWS ARE TO BE PREFINISHED METAL GLAD WINDOWS WITH DOUBLE -PANE,
<br />"LOW -E" INSULATED GLASS AND SIMULATED DIVIDED LITES ON BOTH SIDES OF GLASS WITH SPACER BARS
<br />(ASSUME 11/8" S.D.L. MUNTIN BARS), PRE -FINISHED COLOR AND HARDWARE FINISH AS SELECTED BY OWNER (BID
<br />OIL -RUBBED BRONZE). WINDOWS TO BE SIMILAR IN SIZE AND SPECIFICATION TO THOSE INDICATED ON THE
<br />ARCHITECTURAL DRAWINGS. WINDOW MANUFACTURER SHALL SUBMIT SHOP DRAWINGS OF ALL CUSTOM
<br />WINDOWS AND DOORS TO G.G. AND OWNER FOR REVIEW PRIOR TO FABRIGATION.
<br />17. CABINET DRAWINGS... (TBD) ....ARE NOT CABINET SHOP DRAWINGS, BUT DEPICT DESIGN INTENT ONLY.
<br />CABINET MANUFACTURER TO COORDINATE FINAL CABINET DESIGN WITH AS -BUILT DIMENSIONS (FIELD -VERIFY),
<br />WITH FIELD CHANGES MADE DURING CONSTRUCTION, WITH FINAL MILLWORK PROFILES, WITH FINAL
<br />GOUNTERTOP THICKNESS AND DESIGNS, AND WITH FINAL APPLIANCE AND FIXTURE SELECTIONS. CABINET
<br />MAKER TO VERIFY END PANEL DESIGNS AND CABINET CLEARANCES WITH OWNER PRIOR TO CABINET
<br />FABRICATION. GABINET MAKER TO MEET WITH OWNERS TO DISCUSS AND VERIFY ALL DRAWER AND GABINET
<br />DIVISIONS AND USES, INCLUDING PULLOUT LOCATIONS, SPICE PARTITION LOCATIONS, LAZY SUSAN LOCATIONS,
<br />GUTTING BOARD LOCATIONS, COST RAMIFICATIONS, AND ANY OTHER SUGGESTIONS THE GABINET MAKER OR
<br />OWNER MAY HAVE FOR MAXIMIZING CABINETRY EFFICIENCY AND EASE OF USE. ALSO GONFIR" GABINET
<br />HARDWARE QUANTITIES AND OPERATION FOR HINGES / DRAWER GLIDES, AND KNOB LOCATIONS.
<br />SUBCONTRACTORS TO REFER TO APPROVED GABINET SHOP DRAWINGS PRIOR TO ROUGH FRAMING FOR
<br />GABINETS/BUILT-INS. REPORT ANY DISCREPANCIES TO G.G., OWNER AND GABINET MAKER PRIOR TO
<br />PROGEEDING WITH WORK.
<br />18. GENERAL CONTRACTOR TO COORDINATE OWNERS, REVIEW AND APPROVAL OF SAMPLES OF ALL INTERIOR
<br />AND EXTERIOR FINISH MATERIALS, INCLUDING PROFILES, SIZES, SPECIES, MORTAR AND GROUT COLORS, JOINT
<br />SIZES, FINISHES AND COLORS PRIOR TO ORDERING OF SAME. SAMPLES SHALL BE PROVIDED ON-SITE
<br />HOMEOWNER DEEMS NECESSARY, AND IN SIZE LARGE ENOUGH TO SEE IN THE FINAL SPACE (E.G. 4'X4' WALL
<br />PAINT SAMPLES, AND STAINED AND FINISHED WOOD FLOOR SAMPLES). G.G. TO COORDINATE OWNERS' REVIEW
<br />AND APPROVAL OF MOCKUPS OF INTERIOR AND EXTERIOR CASTINGS, TRIM, NEWELS, AND RAILINGS PRIOR TO
<br />CONTRACTOR ORDERING OF SAME (ON SITE WHEN OWNER DEEMS NECESSARY). OWNER TO REVIEW AND
<br />APPROVE MOCKUPS OF ALL STONE ON SITE, INCLUDING SIZE 8F SPECIES, MORTAR JOINT SIZE, MORTAR COLOR.
<br />STONE STAGK, GAP SPECIES AND SIZE. STONE SAMPLES SHALL BE DISPLAYED ALONGSIDE RELEVANT INTER
<br />AND EXTERIOR FINISH MATERIALS, AS REQUIRED FOR FINAL COLOR PALLET COORDINATION. G.G. SHALL
<br />COORDINATE OWNERS COUNTERTOP SELECTIONS, AND SHALL VERIFY THAT NATURAL STONE SLABS THAT
<br />OWNER SELECTS ARE PROPERLY STORED, AND USED IN THE FINAL PROJECT.
<br />19. DIMENSIONS LOCATING EXTERIOR WALLS ARE TO THE EXTERIOR FACE OF SHEATHING AND/OR FACE OF
<br />FOUNDATION WALLS, UNLESS NOTED OTHERWISE. DIMENSIONS LOCATING INTERIOR WALLS ARE TO
<br />CENTERLINE OF STUD, UNLESS NOTED OTHERWISE. DIMENSIONS LOCATING DOORS AND WINDOWS ARE TO
<br />CENTERLINE OF OPENING, UNLESS NOTED OTHERWISE.
<br />20. ALL EXTERIOR WALLS SHALL BE 2x0 AS PER BUILDING SECTIONS, U.N.O. ALL BEARING WALLS, PLUMBING
<br />WALLS, AND WALLS WITH POGKET DOORS TO BE 2x0 CONSTRUCTION, U.N.O. ALL OTHER WALLS TO BE 2x4
<br />CONSTRUCTION TO THIGKNESS SHOWN ON ARCHITECTURAL AND STRUCTURAL DRAWINGS, U.N.O. HEADERS
<br />SHALL SIZED PER STRUCTURAL PLANS, OR COORDINATED WITH STRUCTURAL ENGINEER. BLOCKING AS
<br />REQUIRED FOR CABINETS, BATH AND KITCHEN HARDWARE AND ACCESSORIES, HANDRAILS, ETC. VERIFY
<br />BLOCKING LOCATIONS W/G.G. PRIOR TO FRAMING.
<br />21. SITE PLAN AND RELATED INFORMATION PROVIDED BY SURVEYOR IS USED HERE TO SHOW DESIGN INTENT
<br />ONLY. VERIFY ALL CONDITIONS AND DIMENSIONS W/ SURVEYOR.
<br />22. PROVIDE ACOUSTIC INSULATION AND PARTITIONS PER ARCHITECTURAL DRAWINGS. CONTRACTOR TO VERIFY
<br />ACOUSTIC INSULATION LOGATIONS W/OWNER PRIOR TO VAPOR BARRIER $. DRYWALL INSTALLATION. AGOUSTIG
<br />CONSIDERATION TO BE GIVEN TO HVAG DUCT LAYOUTS AND PLUMBING LOCATIONS, AND ACOUSTIC
<br />DAMPENING TO BE PROVIDED TO HVAG SYSTEM AND PLUMBING WASTE STACKS AS REQUIRED TO MINIMIZE
<br />SOUND TRANSMISSION.
<br />23. PLUMBING ROUGH -IN DIMENSIONS ARE PROVIDED FOR REFERENCE ONLY. ALL PLUMBING DIMENSIONS ARE
<br />TO BE COORDINATED BY THE GENERAL CONTRACTOR AND/OR PLUMBING SUBCONTRACTOR WITH SPECIFIC
<br />FIXTURE SELECTIONS AND FINAL GABINET DESIGN. ALL FLOOR DRAINS CONNECTED TO SANITARY SEWER TO
<br />HAVE BAGK-FLOW PREVENTERS INSTALLED.
<br />24. MECHANICAL EQUIPMENT 8,: CONTROL LOCATIONS TO BE VERIFIED WITH OWNER PRIOR TO INSTALLATION -
<br />SEE DRAWINGS FOR PROPOSED LOGATIONS. MAKEUP AIR TO BE PROVIDED AS PER LR.G. AND ANY OTHER
<br />APPLICABLE CODES. SUPPLY AND RETURN REGISTER COVERS TO BE APPROVED BY OWNER - ASSUME FLUSH
<br />WOOD VENTS TO MATCH WOOD FLOOR SPECIES 8.: FINISH FOR BID. WHERE AFFECTED BY MECHANICAL DUCTS
<br />AND EQUIPMENT, CEILING HEIGHTS AND SOFFIT SIZES AND LOCATIONS TO BE APPROVED BY OWNER PRIOR TO
<br />INSTALLATION OF HVAG DUCTS AND EQUIPMENT. ALL VENT AND GRILLE LOCATIONS TO BE APPROVED BY
<br />OWNER PRIOR TO INSTALLATION.
<br />25. DOOR 8,: DOOR HARDWARE 8,: WINDOW SCHEDULE SHALL BE BY GENERAL CONTRACTOR. G.G. TO SUBMIT
<br />SHOP DRAWINGS FOR OWNER AND ARCHITECT REVIEW AND APPROVAL PRIOR TO FABRGATION.
<br />A- Al
<br />INTERIOR AND
<br />EXTERIOR
<br />ool
<br />DOOR TAG
<br />O KEY NOTES
<br />201
<br />ELEVATIONS
<br />FOUNDATION PLAN
<br />A5
<br />SPORT COURT PLAN
<br />AC
<br />BUILDING AND
<br />ool
<br />WINDOW
<br />s d REVISION TAG
<br />UPPER LEVEL FLOOR PLAN
<br />WALL SECTIONS
<br />ROOF PLAN
<br />TAG
<br />EXTERIOR ELEVATIONS
<br />All
<br />EXTERIOR ELEVATIONS
<br />Al2
<br />BUILDING SECTIONS
<br />A13
<br />IOTA EQUIPMENT
<br />Col ELEGTRIGAL AND
<br />BUILDING SECTIONS
<br />A15
<br />BUILDING DETAILS
<br />TAG
<br />LIGHTING
<br />A21
<br />INTERIOR ELEVATIONS
<br />A22
<br />INTERIOR ELEVATIONS
<br />FIXTURE TAG
<br />1
<br />GRIDS
<br />333A
<br />PLUMBING
<br />0,2 WALL TAG
<br />X
<br />TAG
<br />MASTER
<br />ELEVATION HEIGHT
<br />CENTER LINE
<br />CLOSET
<br />333 ROOM TAG
<br />150 SF
<br />s h a t r a
<br />4d S61
<br />company i Am�_ !I
<br />404 SECOND STREET PHONE: 952-470-9750
<br />SUITE 100 FAX: 952-707-5859
<br />EXCELSIOR, MN 55331 info@sharrattdesign.com
<br />SHEET INDEX
<br />Al
<br />COVER SHEET
<br />A2
<br />SITE PLAN
<br />A3
<br />ENLARGED SITE PLAN AT HOUSE
<br />A4
<br />FOUNDATION PLAN
<br />A5
<br />SPORT COURT PLAN
<br />AC
<br />LOWER LEVEL. FLOOR PLAN
<br />AT
<br />MAIN LEVEL FLOOR PLAN
<br />AB
<br />UPPER LEVEL FLOOR PLAN
<br />AS)
<br />ROOF PLAN
<br />A10
<br />EXTERIOR ELEVATIONS
<br />All
<br />EXTERIOR ELEVATIONS
<br />Al2
<br />BUILDING SECTIONS
<br />A13
<br />BUILDING SECTIONS
<br />A14
<br />BUILDING SECTIONS
<br />A15
<br />BUILDING DETAILS
<br />A20
<br />INTERIOR ELEVATIONS
<br />A21
<br />INTERIOR ELEVATIONS
<br />A22
<br />INTERIOR ELEVATIONS
<br />A23
<br />INTERIOR ELEVATIONS
<br />A24
<br />SCHEDULES
<br />PROJECT TEAM
<br />ARCH ITEGT
<br />SHARRATT DESIGN � GO"PANY
<br />404 SECOND ST - SUITE 100
<br />EXCELSIOR, MN 55331
<br />CONTACT: MIKE SHARRATT / NICHOLAS COWAN
<br />STRUCTURAL ENGINEER
<br />WENZEL ENGINEERING ING.
<br />10100 MORGAN AVE SOUTH
<br />BLOOMINGTON, MN 55431
<br />STEVE RIVARD - _952-888-051G
<br />GENERAL GONTRAGTOR
<br />JOHN KRAEMER �. SONS, INC
<br />4900 LINCOLN DRIVE
<br />EDINA, MN 55430
<br />JEFF KRAEMER - 952-935-9100
<br />ISSUED FOR
<br />ISSUE DATE
<br />�z
<br />w
<br />5
<br />0
<br />w
<br />Z
<br />w-1(
<br />U1
<br />Of
<br />Q
<br />m
<br />ci
<br />O
<br />U
<br />D
<br />U
<br />0)
<br />W�-
<br />N(
<br />m�
<br />I-
<br />(j)
<br />Z
<br />()
<br />Of
<br />0
<br />Z
<br />0
<br />Q
<br />�
<br />Z
<br />O
<br />U
<br />Q�L
<br />r
<br />Z=
<br />OC
<br />O
<br />05/19/17
<br />X
<br />07/24/17
<br />X
<br />08/30/17
<br />X
<br />PROPOSED NEW HOME FOR:
<br />HENNEN
<br />HOME
<br />2025 KELLY AVENUE
<br />ORONO, I -IN
<br />SHEET
<br />LEGAL NOTICE
<br />THESE DOCUMENTS SHALL NOT BE REPRODUCED OR REDISTRIBUTED
<br />WITH OUT EXPRESSED WRITTEN CONSENT OF SHARRATT DESIGN AND
<br />COMPANY, LLC.
<br />,c COPYRIGHT 2016 SHARRATT DESIGN s£ COMPANY LLC.
<br />
|